21
Editing a Patch
The Edit Parameter table on the next
pages shows all the parameters that
can be edited with the Kiwitechnics
3P Matrix Upgrade.
Note – the Group buttons
mentioned here refer to the
buttons A-D that are used for tone
selection and not the buttons
labelled GROUP A and GROUP B
on the original 3P front panel.
Use the menu map as a guide to the
editing key sequence. For example
to edit the ENV2 Attack Rate press
EDIT PARAM, GROUP D, BANK 1
then TONE 5 and edit the value
using the Sense Slider. Press
CANCEL or EDIT PARAM again to
exit edit mode.
To change from Parameter Editing
to Global editing long press the
TONE GROUP A button. Long press
TONE GROUP A again to return
from Global editing to parameter
editing.
The first digit (e.g. B:3:4) is the
Group A-D and is selected using the
four Group buttons.
The second digit of the parameter
ID is selected using the BANK
buttons 1-4.
The third digit of the parameter ID is
selected using the TONE buttons 1-
8.
The current parameter being edited
is displayed as follows.
The First letter A-D is displayed on
the GROUP buttons.
The second digit is displayed on the
BANK buttons as a flashing light
and the third digit is also displayed
on the BANK buttons as a steady
light. This is done so that the value
of the parameter can be displayed
using the TONE lights.
If the second and third digits of the
parameter are the same (e.g. A:1:1)
then the third digit will override the
second and only a steady light will
show.
Controls that have 0-127 or 0-4095
steps will display as 1-8. This
doesn't mean the number of steps is
reduced.
All Parameters are edited using the
Sens control unlike the original 3P
which used the Bank buttons to set
switches. These are now changed
using the Sens slider as well.
Note - The behaviour of the Sens
control during parameter editing
has been changed from the way the
original 3P works. When editing a
parameter the current value of the
parameter must be matched before
the Sens Control will have any effect
on the parameter value.
e.g. if the filter cutoff is set to 7 the
Sens must be moved to 7 before it
will begin to edit the setting. This
has been done so that a parameter
will not jump to the Sens setting
which can cause unpredictable and
sometimes unpleasant results.
Raising a control towards 10 will
deepen an effect.
Kiwi-3P Matrix Upgrade User Manual v1.2