69
Table 1.0 Command ID
Data Byte
Data Type
Byte details
7 ------- 0
Data Details
$06 (6) Transmit/Receive Library
Tone Dump
Bank + Tone + 118 data bytes
Bank Number
000000xx
xx =
0 for Tones 1-128
1 for Tones 129-256
2 for Tones 257-384
3 for Tones 385-512
WARNING! This command will overwrite
the current sounding Tone with
the Tone selected
Tone Number
0xxxxxxx
x =
0-127
for Tone 1-128
JX-10/MKS-70 transmits/receives data in the same format
as the $04 Command
$09 (9) Request Seq Dump
Seq Number
Sequence Number
000xxxxx
x =
0-7 for Sequence 1-8
JX-10/MKS-70 transmits a $0a (10) command with 1659 data
bytes
WARNING! This command will overwrite
the current sounding Seq with
the Seq selected
$0a (10)Transmit / Receive Seq
Dump
Seq 1659 data bytes
Sequence Number
000xxxxx
x =
0-7
WARNING! This command will overwrite
the current sounding Seq with
the Seq selected
$00-$13 (0-19) = Seq Name
20 Ascii Bytes
Sequence Name
$14 (20) = Seq Length
0xxxxxxx
x =
0 = No Seq Recorded
1-124 = No of Seq Steps
$15-$2e (21-46) = Reserved
26 bytes Reserved for future expansion
$2f-$67b (47-1659) = Seq Steps
124 x 13 (1612)
Note 1 0xxxxxxx
Note 2 0xxxxxxx
Note 3 0xxxxxxx
Note 4 0xxxxxxx
Note 5 0xxxxxxx
Note 6 0xxxxxxx
Byte 7 00abcdef
Byte 8 0xxxxxxx
Byte 9 0xxxxxxx
Byte 10 0xxxxxxx
Byte 11 0xxxxxxx
Byte 12 0xxxxxxx
Byte 13 0xxxxxxx
Step is 13 bytes
Byte 1-6 xxxxxxx = note number (32-96)
Note Bytes are $00 (0) if not used
Byte 7 a-f is tie bits 1-6 (set if tie set)
Byte 8-13 xxxxxxx = voice 1-6 Level (0-127)
Seq 0-7 can have a maximum of 124 steps
www.kiwitechnics.com
JX-10/MKS-70 Upgrade User Manual v100
Summary of Contents for Kiwitechnics KIWI-SJX
Page 1: ......
Page 6: ...Kiwi SJX JX 10 Flow Chart...
Page 7: ...Kiwi SJX MKS 70 Flow Chart...
Page 8: ...Kiwi SJX JX 10 Front Panel...
Page 9: ...Kiwi SJX MKS 70 Front Panel...
Page 89: ...89 www kiwitechnics com JX SJX Upgrade User Manual v100...