Optimizing the Printing Quality
23
Chapter 1 Fully Utilizing the Machine
If the printing-test results are difficult to interpret
Examine the results from different angles in a well-lit location . Take advantage of reflected light
to enable visual checking . Alternatively, change the media and perform the printing again .
If you cannot see "H3" and "H4" (such as for white media with no luster)
You may not be able to see "H3" or "H4" when using certain media, such as white media with no
luster . In this situation, set "H3" and "H4" to the "H2" value .
2.
Press [ ] .
3.
In the same manner as performed for [SETTING NO .1], set the correction values for [SETTING NO .2] to
[SETTING NO .4] .
DETAIL SETTING
SETTING NO.2
4.
When you have finished setting the correction values, press [ENTER] .
5.
Close the front cover .
If you are using rigid media, press [ ] to bring back the media to an appropriate position .
6.
Press [MENU], then [ ] to go back to the original screen .
W:770mm L:330mm
H:100mm
H4
0
H1 H2 H3
-2 1 3