Handling Messages and Error Messages
87
Chapter 3 Appendix
An Error Message Appears
This section describes the error messages that may appear on the machine's display and how to take action
to remedy the problem. If the action described here does not correct the problem or if an error message not
described here appears, contact your authorized Roland DG Corp. dealer.
Message
Explanation
Action
AREA TOO SMALL
CONTINUE?
The size of the data is
larger than the print area
of the loaded media
To continue printing without correcting this, press [ENTER]. The
portion extending beyond the print area will not be printed. To
stop printing, stop sending data from the computer and hold down
[SETUP] for one second or longer. Make the print area wider by
replacing the media with a larger piece of media or by changing
the position of the media, and then send the data again.
PRINT AREA TOO SMALL
The size of the test print is
larger than the print area
of the loaded media.
Press any key on the operation panel to go back to the main menu.
Make the print area wider by replacing the media with a larger
piece of media or by changing the position of the media, and then
send the data again.
CANCELED FOR TABLE
HEIGHT
The media was detected
in a position (at a height)
at which it hits the print
heads.
Press any key (except the sub power switch) on the operation panel
to make the message disappear. If the setup of the media has been
completed, the setup is canceled. Redo the setup.
"
"1. Loading Media (Media Setup)" (First Step Guide)
"
"2. Setting the Height of the Media Automatically" (First Step
Guide)
"
“Setting the Height of the Media Manually” (p. 9)
"
“Changing the Print Area” (p. 13)
"
“Continuing Printing Even If Media Comes into Contact with
the Head Gap Sensor” (p. 27)
CHECK TABLE HEIGHT
Remove the media (remove the cause of the failure) or change its
position.
After verifying the message, press [ENTER].
"
"1. Loading Media (Media Setup)" (First Step Guide)
"
"2. Setting the Height of the Media Automatically" (First Step
Guide)
"
“Setting the Height of the Media Manually” (p. 9)
"
“Changing the Print Area” (p. 13)
"
“Continuing Printing Even If Media Comes into Contact with
the Head Gap Sensor” (p. 27)
TEMPERATURE IS TOO HIGH
**°C
The temperature of
the location where the
machine is installed has
risen above the ambient
temperature at which the
machine can operate.
Operation cannot be continued. Turn off the sub power. The
displayed temperature is the current ambient temperature of the
installation location. Bring the installed location to a temperature
at which operation is possible (20 to 32°C [68 to 90°F]), and then
turn on the power.