17
ESC.E Err13: Out of
Parameter range
Appears if the value for a device control instruction parameter
exceeds the permissible limit.
ESC.E Err14:
Termination Error
Appears
i f
the number of parameters for a device control instruction is more than
that permissible .
ESC.E Err15:
Framing/Parity Error
Appears if a framing error, parity error, or overrun error occurs at the
time of data reception.(There is a problem with one of these settings:
Baud Rate, Parity, Stop Bits, or Data Bits. The protocol settings for
the PNC-1050 must be made correctly in order to match the settings
your computer is set to use.)
ESC.E Err16 Buffer
Troubleshooting
Overflow
Appears if the I/O buffer has overflowed. (There is a problem with the
connecting cable, or the settings for Handshaking. Make sure you are using
a cable appropriate for the computer being used. Also, check that the
setting for Handshaking is correct.)
ESC.E Err18
Indeterminate Error
Appears if a communication error other than “ Err10 “ through
“ Err16 “ , one uninterpretable by the PNC-1050, occurs during data
communications.
Power not supplied to unit.
• Check to make sure the power cord is connected properly.
Firmly connect the power supply cord to the unit.
• Recheck the power switch. Is it actually at ON?
Turn on the power supply switch.
Unit does not operate even when Cutting data is downloaded from computer.
• Faulty connection between computer and PNC-1050.
Firmly connect the connecting cable between the unit and the computer.
• The power supply switch is not on.
Turn on the power supply switch.
• Interface type settings do not match.