3 Replacement of Main Parts
3-28
3
2
4
1
3
3-7 INK TUBE REPLACEMENT
Turn on the SUB POWER SW and perform the [PUMP
UP] from the [INK CONTROL] menu.
W h e n i t f i n i s h e s , t h e S U B P O W E R w i l l b e
automatically turned off.
Turn on the SUB POWER SW while pressing the Left,
Right and Down keys to enter the SERVICE MODE.
INK CONTROL
EMPTY MODE
MENU
INK CONTROL
INK CONTROL
PUMP UP
[MENU] key
[ ], [ ], [ ] + POWER ON
MENU
SERVICE MENU
[ ]
[ ]
[ENTER]
SERVICE MENU
CAP&WIPER CTRL
CAP&WIPER CTRL
CAP
CAP
OPEN
Select [CAP&WIPER CTRL] > [CAP] > [OPEN], and
press the [ENTER] key.
Turn off the SUB POWER SW, and then turn off the
MAIN POWER SW.
MAIN POWER SWITCH
Summary of Contents for SP-300
Page 128: ...2 Electrical Section 2 2 2 2 2 MAIN BOARD DIP SW DIP SW bit 1 bit 8 Always OFF ...
Page 134: ...2 Electrical Section 2 8 2 2 3 SERVO BOARD ...
Page 135: ...2 Electrical Section 2 9 2 ...
Page 140: ...2 Electrical Section 2 14 2 2 4 HEATER BOARD ...
Page 189: ...3 Replacement of Main Parts 3 42 3 9 Carry out the LINEAR ENCODER SETUP ...