4-31
4 Adjustment
4
4
When Linear Encoder Setup is completed, carry out the
[LINEAR CALIB.] in the Service Menu.
SERVICE MENU
LINEAR CALIB.
NOW PROCESSING..
LINEAR CALIB.
SETUP COMPLETED
LENEAR CALIB.
0.18%
[ENTER]
LINEAR CALIB.
SETUP FAILED
In case of an error, check the followings.
5
1. Dirt/Scratch on the ENCODER SCALE.
2. Dirt/Scratch on the ENCODER MODULE.
3. ENCODER SCALE is not between the
ENCODER MODULE.
4. Backlash of the CARRIAGE MOTOR GEAR
and the DRIVE GEAR.
5. Fixation between the CARRIAGE and the
CARRIAGE WIRE.
6. Bad Contact in the cables.