Settings for the Entire TD (SYSTEM)
41
Optimizing the Pad Settings (Pad Settings)
1.
In step 4 of the basic procedure (p . 34), choose “Pad Settings” and then press the [F3] (ENTER) button to access
the PAD SETTINGS screen .
2.
Choose one of the following items to edit .
Button
Description
Page
[F1] (TYPE)
Specify the type of pad
[F2] (BASIC)
Adjust the pad sensitivity
[F3] (ADVNCD)
Make advanced settings for the trigger parameters
3.
Strike a pad to select the pad for which to make settings .
4.
Use the cursor buttons ( / ) to select a parameter, and use the value dial to edit the value .
Specifying the Type of Pad [F1] (TYPE)
You can select the type of pad you’re using (Pad Type) so the TD will accurately receive the signal from the pad.
Parameter
Value
Description
Pad Type
KD-7, KD-8, KD-9, KD-120, KD-140,
PD-8, PD-85, PD-105, PD-108, PD-125, PD-128, PDX-6, PDX-8,
PDX100,
CY-5, CY-8, CY-12C, CY-13R, CY-14C, CY-15R, VH-11,
RT-10K, RT-10S, RT-10T
The pad type is a collection of parameters optimized for
specific models of pad.
If you select the appropriate trigger type for each pad you’ve
connected, all parameters (except for Crosstalk Cancel) will be
set to the optimal values.
However, these are only the typical values, so you may need to
make fine adjustments according to how you’ve attached the
pads or the way in which you’re using them.
The following pads should be connected to the “SNR,” “T1–3,” or “AUX” trigger input.
If these pads are connected to any other trigger input, the signal of a rim strike will not be detected correctly.
Pads
PD-85, PD-105, PD-108, PD-125, PD-128,
PDX-6, PDX-8, PDX-100,
RT-10S