6
On the head of the PD-100 or PD-120, accurately strike a location approximately 1 inch (3 cm) from
the tuning bolt.
fig.00-027e
The indicator in the lower right of the display will indicate how far off the adjustment is.
7
Use a tuning key (optional) to turn the all tuning bolt so that the indicator reaches the position shown
in the diagram.
fig.00-027ae
If the indicator is toward the right, turn the tuning key toward the left to loosen the tension. If the
indicator is toward the left, turn the tuning key toward the right to tighten the tension.
If the indicator moves greatly to the left or right, adjust the tension of the entire head before making this set-
ting.
The head tension adjustment does not work correctly when the “SCAN TIME” (p. 111) setting is excessively
low. The “SCAN TIME” setting is automatically set to the most efficient values for each pad when you select
the “TRIGGER TYPE” (P.108). If you have changed the “SCAN TIME” setting, select the “TRIGGER
TYPE” again.
For details on adjusting the head tension, refer to the PD-100/120 owner’s manual.
Once you have completed your settings, press [EXIT] enough times to get back to the “DRUM KIT”
page.
1 inch (3 cm)
Strike here
Tuning bolt
Indicator
NOTE
MEMO
Before you begin playing
32
Summary of Contents for V-DRUMS TD-10
Page 21: ...Quick Start Quick Start 21...
Page 131: ...Appendices Appendices 131...