4
KIT EDIT
INSTRUMENT
Here you can make detailed settings for an instrument.
Parameters Common to Each Instrument
Parameter
Value
Explanation
[F1] button (INST tab)
Inst
001–728 (preset)
U001–U500 (user sample)
Instrument number
&
Refer to “Instrument List” (p. 50).
[F2] button (EDIT tab)
Pad Pitch
-4800–4800
Instrument pitch (units of one cent)
Pad Pitch Sweep *1
-100–100
After the sound begins, the pitch gradually rises (falls).
Positive (+) values make the pitch start high and then fall; negative (-) values make the pitch start
low and then rise.
Larger values produce greater change.
* In some cases, changing the Pad Pitch setting by a large amount might limit the Pad Pitch Sweep
effect.
Pad Decay *1
1–100
Length of decay
Dynamic Enhancer Sw *1
OFF, NORMAL, WIDE
Specifies whether the sense of strong strikes is enhanced (NORMAL, WIDE) or not enhanced (OFF).
The WIDE setting supports performance with higher velocities (this is ideal when used with pads
that support a digital connection).
*1: If a user sample is assigned to the instrument, you can’t specify Dynamic Enhancer Sw. Also, if the user sample’s Play Type (p. 23) is set to “LOOP ALT,” the Pad Pitch Sweep and
Pad Decay have no effect.