To play the PDX-100 efficiently

•  BEFORE playing the pad, you must tension the head. 

See Page 5.

•  Trigger type and trigger parameters in the sound 

module must be adjusted. See Page 6.

Adjusting the Head Tension

Before using the pad, tighten the head so that the 

tension is rather firm.
Looseness in the head tension may result in problems 

such as failure of the PDX-100’s rim shots to sound or 

double triggering.

NOTE

Striking the head when the head tension is loose may 

damage the sensor.

1. 

Use the included drum key to tighten the tuning 

bolts.

Strike the head to check the feel and response.

Tighten

Loosen 

Tighten each tuning bolt one by one, observing 

the numerical order shown in the diagram. 

Do not firmly tighten a single tuning bolt by itself. Doing 

so will make it impossible to tension the head evenly, 

and will cause malfunctions.

5

3

4

6

2

1

2. 

Fine-tune the adjustment while continuing to 

check the pad feel and response.

MEMO

•  On the PDX-100, adjusting the head tension affects 

only the head response, and does not change the 

pitch of the sound as it would on an acoustic drum.

•  Head tension may slacken with the passage of time. 

Readjust the tension as needed.

Attaching the Pad to a Stand

The PDX-100 can be attached to a stand that has either a 

vertical rod or a horizontal pipe.

Stand with vertical rod (MDS series)

Loosen

Tighten

Acceptable rod diameters:

 9.0–13.0 mm (3/8 to 9/16 inch)

Stand with horizontal pipe

Loosen

Tighten

Usable pipe size:

 22.2 mm (7/8 inch)

Using the PDX-100

Summary of Contents for V-Pad PDX-100

Page 1: ......

Page 2: ...w this product to cause the stand to overturn Please be mindful of any safety issues before using this product 104 Manage cables for safety Try to prevent cords and cables from becoming entangled Also all cords and cables should be placed so they are out of the reach of children 106 Avoid climbing on top of the unit or placing heavy objects on it Never climb on top of nor place heavy objects on th...

Page 3: ...dirt use a cloth impregnated with a mild non abrasive detergent Afterwards be sure to wipe the unit thoroughly with a soft dry cloth 402 Never use benzine thinners alcohol or solvents of any kind to avoid the possibility of discoloration and or deformation Additional Precautions 553 Use a reasonable amount of care when using the output jack Rough handling can lead to malfunctions 556 When disconne...

Page 4: ... Specifications Roland PDX 100 V Pad Head Size 10 inches Triggers 2 Head Rim Dimensions 310 W x 325 D x 90 H mm 12 1 4 W x 12 13 16 D x 3 9 16 H inches Weight 1 8 kg 4 lbs Accessories Owner s Manual Connection Cable Drum Key Options Pad Mount MDH series Drum Stands MDS series 962a In the interest of product improvement the specifications and or appearance of this unit are subject to change without...

Page 5: ...observing the numerical order shown in the diagram Do not firmly tighten a single tuning bolt by itself Doing so will make it impossible to tension the head evenly and will cause malfunctions 5 3 4 6 2 1 2 Fine tune the adjustment while continuing to check the pad feel and response MEMO On the PDX 100 adjusting the head tension affects only the head response and does not change the pitch of the so...

Page 6: ...TD 4 MEMO For details refer to the owner s manual of your percussion sound module Recommended parameter settings Below please find recommended trigger parameter settings when using the PDX 100 with various sound modules Further trigger parameter adjustment may be needed depending on the way in which the PDX 100 is mounted or the playing environment For details on editing refer to the owner s manua...

Page 7: ...Only playing the head and with certain snare sounds the playing position will change the sound s nuance MEMO Refer to the owner s manual of your percussion sound module for more info about which sounds allow this Rim shots Strike the head and the rim of the pad simultaneously You can play a different sounds rim sounds from when you strike the head Cross stick Only strike the rim of the pad Dependi...

Page 8: ...8 ...

Page 9: ... Instrumentos Musicales J E Olear y ESQ Manduvira Asuncion PARAGUAY TEL 595 21 492147 PERU Audionet Distribuciones Musicales SAC Juan Fanning 530 Miraflores Lima PERU TEL 511 4461388 TRINIDAD AMR Ltd Ground Floor Maritime Plaza Barataria TRINIDAD W I TEL 868 638 6385 URUGUAY Todo Musica S A Francisco Acuna de Figueroa 1771 C P 11 800 Montevideo URUGUAY TEL 02 924 2335 VENEZUELA Instrumentos Musica...

Reviews: