4-36
4-7 FLUSHING POSITION ADJUSTMENT (Referential Time : 5min.)
This is to adjust the flushing position. This adjustment is required when a Cap Top and a head are removed
or replaced. Without this adjustment, the Flushing may not be performed properly.
2
I/S COVER
SCREWs
HOOK
Remove the I/S Cover.
Turn on the Sub Power SW while pressing [ ], [ ] and
[ ] keys to enter the Service Mode.
3
MENU
SERVICE MENU
+
MENU
1
For VP-540, the Head height should be set LOW.
LOW
HIGH