6-13 ERROR MESSAGE
NO
CHECKING
ACTION
REFERENCE
OUTLINE
Restart the machine
Restart the machine and see if the same error occurs again.
Refer to [6-14 SERVICE
CALL]
[6-14 SERVICE CALL]
Restart the machine
Restart the machine and see if the same error occurs again.
Upgrade the firmware to
the latest version
Check the revision record of the firmware version and
upgrade it if the error has been solved in the firmware.
6-14 SERVICE CALL
CODE
CAUSE
ACTION
0002
Servo Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main
Board and Servo Board.
Check cable connection between Main Board and Servo
Board.
Check the other cable connections of Servo Board.
Servo Board replacement
Main Board replacement
Flexible cable replacement
0004
SRAM is broken.
Servo Board replacement
0005
Servo Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main
Board and Servo Board.
A noise on a signal.
Check cable connection between Main Board and Servo
Board.
Check the other cable connections of Servo Board.
Servo Board replacement
Main Board replacement
Flexible cable replacement
0006
A noise on a signal while sending a
command.
Sub CPU was reset to default.
Tried to communicate when Sub CPU was
reset to default.
Check cable connection between Main Board and Servo
Board.
Check the other cable connections of Servo Board.
Servo Board replacement
Main Board replacement
Flexible cable replacement
0007
Servo Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main
Board and Servo Board.
A noise on a signal while sending a
command.
Sub CPU was reset while sending a
command.
Check cable connection between Main Board and Servo
Board.
Check the other cable connections of Servo Board.
Servo Board replacement
Main Board replacement
Flexible cable replacement
0008
Servo Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main
Board and Servo Board.
A noise on a signal.
Check cable connection between Main Board and Servo
Board.
Check the other cable connections of Servo Board.
Servo Board replacement
Main Board replacement
Flexible cable replacement
0010
Network I/F does not work correctly.
Firmware for Network I/F is not installed.
Check the firmware is installed into Network I/F.
Main Board replacement
0101
Limit Position Initialize has not been done.
Limit Position Initialize is ended before it is
completed.
Complete Limit Position Initialize correctly.
0102
Head Lock Sensor does not work correctly or
is broken.
Head Lock Sensor replacement
Check the mechanical backlash or loose with the scan axis
related parts.
0103
Limit Sensor does not work correctly or is
broken.
Limit Sensor replacement
Check the mechanical backlash or loose with the scan axis
related parts.
0105
Fault of Tool Carriage Connection
Loose of Connection Part
Fault of the Limit Position Initialize value
Limit Sensor does not work correctly or is
broken.
Check the mechanical Backlash or loose with the Tool
Carriage part.
Connection Part Replacement
Limit Position Initialize
0106
Fault of Tool Carriage Connection
Loose of Connection Part
Fault of the Limit Position Initialize value
Limit Sensor does not work correctly or is
broken.
Check the mechanical Backlash or loose with the Tool
Carriage part.
Connection Part Replacement
Limit Position Initialize
0107
Linear Encoder Setup has not been done.
Linear Encoder Setup is ended before it is
completed.
Carry out Linear Encoder Setup in service menu.
6-10
Disorder of communication with Sub CPU
This occurs when the Sub CPU is not
detected after turning on the machine
An error occurs while downloading a
program for sub CPU.
An error occurs when trying to connect with
sub CPU.
An error occurs while sending a command.
There is a problem with synchronizing serial
communication to Sub CPU.
Network I/F Initialize has not been
completed.
Limit Position Initialize in the Service Mode
has not been done.
Linear Encoder Setup has not been done.
Machine fails to disconnect the Tool
Carriage from the Head Carriage.
Tool Carriage Connection Error
Even though the machine carries out the
regular movement, the output of Head Lock
Sensor does not reach the expected value.
Even though the machine carries out the
regular movement, the output of Limit Sensor
does not reach the expected value.
1
service call
CONTENTS
Sub CPU SRAM error
Internal Error
2