3-23
Perform the SERVO LOCK CHECK.
After turning on the main power, turn on the sub power
while pressing the left, right and down keys to enter the
Service Mode.
11
12
13
Connect the connector of the Motor Cable.
CONNECTOR
< Top View >
PANEL COVER
< Back Side >
FLEXIBLE CABLE
SENSOR
RIGHT TOP COVER
CHASSIS COVER
Fix the Chassis Cover, Right Top Cover and Panel Cover.
MENU
SERVICE MENU
+
MENU
When fixing the Panel
Cover, fix the sensor on
the back side of the Panel
Cover and connect the
flexible cable to the Panel
Board.
1
2
3
10
Tighten up the 3 screws to fix the Flange in the order
shown in the figure.
Apply a proper quantity of grease (FLOIL G902)
between gears.