1-122
LEF2-300
1
R
EPLACEMENT
Feed Motor Replacement
1.
Turn on the power switch and enter the service mode.
2.
Select [SERVICE MENU] > [MOTOR MENU] > [AXIS MOVE] > [FEED] and set the feed to [Y: 2.8 mm] to move the table to the
backward.
SERVICE MENU
[ ][ ]
MOTOR MENU
AXIS MOVE
AXIS MOVE
FEED
MOTOR MENU
AXIS MOVE
Y:2.8mm
[ ]
[ ]
[ ]
3.
Turn off the power switch, and remove the cover.
4.
Remove the spring that secure the double-gear.
1
1. Double gear