2-51
LEF2-300
2
Adjustment
Calibration (Feed Direction)
4.
A test pattern is printed. Measure the length of the feed direction and use the value to calculate the correction value with
the formula shown at step 5.
NOTE
Test pattern is always printed with correction value 0.00%. Even if a correction is made in the [SETTING] menu, the test
pattern is not affected.
Scan
Feed
500mm
300mm
5.
Calculate the amount to be calibrated with the formula below.
CA = calibration amount
CL = commanded length (300MM)
ML = measured length
Formula
CL - ML
ML
x 100
6.
Select [CALIB. DEFAULT] menu > [SETTING], and press the[
] [
] keys to enter the calibration value. Then press the
[ENTER] key to save the setting.
NOTE
The correction value can be entered in increments of 0.01%.(MAX + 2.00% to MIN-2.00%)
[ ]
SERVICE MENU
PRINT MENU
CALIB.DEFAULT
SETTING
PRINT MENU
CALIB.DEFAULT
[ ]
[ ]
[ ]
[ ]
SETTING
+0.00%
+0.15%
[ ]
7.
(End of procedure)