102
MIDI Implementation
❍
General Purpose Controller 6 (Controller number 81) (Rotary Brake)
Status
2nd byte
3rd byte
BnH
51H
vvH
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
vv = control value:
00H - 7FH (0 - 127) 0-63 = SPIN, 64-127 = BRAKE
*
When signals are received through the MIDI IN connector, reception is over the channel
specified in CONTROL MIDI CH. (p. 77) (factory setting: Channel 1).
*
Not received by the Orchestral Tones part.
*
Not received when MIDI GENERAL CONTROLLERS SWITCH (p. 76) is OFF.
❍
RPN MSB/LSB (Controller number 100, 101)
Status
2nd byte
3rd byte
BnH
65H
mmH
BnH
64H
llH
n = MIDI channel number:
0H - FH (ch.1 - 16)
mm = upper byte (MSB) of parameter number specified by RPN
ll = lower byte (LSB) of parameter number specified by RPN
<<< RPN >>>
Control Changes include RPN (Registered Parameter Numbers), which are extended. When
using RPNs, first RPN (Controller numbers 100 and 101; they can be sent in any order)
should be sent in order to select the parameter, then Data Entry (Controller numbers 6 and
38) should be sent to set the value. Once RPN messages are received, Data Entry messages
that is received at the same MIDI channel after that are recognized as changing toward the
value of the RPN messages. In order not to make any mistakes, transmitting RPN Null is
recommended after setting parameters you need.
This device receives the following RPNs.
RPN
Data entry
MSB, LSB
MSB, LSB
Notes
00H, 00H
mmH, llH
Pitch Bend Sensitivity
mm: 00H - 18H (0 - 24 semitones)
ll: ignored (processed as 00H)
Up to 2 octave can be specified in semitone steps.
* Not received by the Organ part.
00H, 01H
mmH, llH
Master Fine Tuning
mm, ll: 20 00H - 40 00H - 60 00H (-8192 x 50 /
8192 - 0 - +8192 x 50 / 8192 cent)
* Not received by the Organ part.
00H, 02H
mmH, llH
Master Coarse Tuning
mm: 10H - 40H - 70H (-48 - 0 - +48 semitones)
ll: ignored (processed as 00H)
* Not received by the Organ part.
7FH, 7FH
---, ---
RPN null
RPN and NRPN will be set as “unspecified.”
Once this setting has been made, subsequent
Parameter values that were previously set will
not change.
mm, ll: ignored
●
Program Change
Status
2nd byte
CnH
ppH
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
pp = program number:
00H - 3FH (prog.1 - prog.64) (registration)
00H - 07H (prog.1 - prog.8) (Orchestral Tones)
*
Not received when MIDI PROGRAM CHANGE SWITCH is OFF (factory setting: ON).
*
Registrations are received on the channel specified by CONTROL MIDI CH. (p. 77)
(factory setting: channel 1). The Orchestral Tones part is received on the channel
specified by ORCHESTRAL TONES MIDI CH. (factory setting: Upper Orchestral Tones
=channel 4, Lower Orchestral Tones = channel 5, Pedal Orchestral Tones = channel 6).
●
Channel Pressure
Status
2nd byte
DnH
vvH
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
vv = Channel Pressure:
00H - 7FH (0–127)
*
Received only for the Orchestral Tones Part.
●
Pitch Bend Change
Status
2nd byte
3rd byte
EnH
llH
mmH
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
mm,ll = Pitch Bend value:
00 00H - 40 00H - 7F 7FH (-8192 - 0 - +8191)
*
Received only for the Orchestral Tones Part.
■
Channel Mode messages
●
All Sound Off (Controller number 120)
Status
2nd byte
3rd byte
BnH
78H
00H
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
*
When this message is received, all notes currently sounding on the corresponding
channel will be turned off.
●
Reset All Controllers (Controller number 121)
Status
2nd byte
3rd byte
BnH
79H
00H
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
*
When this message is received, the following controllers will be set to their reset values.
Controller
Reset value
Pitch Bend Change ±0 (center)
Modulation 0
(off)
Hold 1
0 (off)
●
All Note Off (Controller number 123)
Status
2nd byte
3rd byte
BnH
7BH
00H
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
*
When All Note Off is received, all currently sounding notes of the corresponding
channel will be turned off. However if Hold 1 is on, the sound will be held until these are
turned off.
■
System Realtime Messages
●
Active Sensing
Status
FEH
*
When an Active Sensing message is received, the unit will begin monitoring the interval
at which MIDI messages are received. During monitoring, if more than 420 ms passes
without a message being received, the same processing will be done as when All Sound
Off, All Note Off, and Reset All Controllers messages are received. Then monitoring will
be halted.
■
System Exclusive Messages
Status
data byte
Status
F0H
iiH, ddH, ......, eeH
F7H
F0H:
System Exclusive message status
ii
=
ID
number:
This is the ID number (manufacturer ID) that specifies the
manufacturer whose exclusive message this is. Roland’s manufacturer
ID is 41H.ID numbers 7EH and 7FH are defined in an expansion of the
MIDI standard as Universal Non-realtime messages (7EH) and
Universal Realtime Messages (7FH).
dd,..., ee = data:
00H - 7FH (0 - 127)
F7H:
EOX (End Of Exclusive) This is the last status of system exclusive
message.
The System Exclusive Messages received by VK-88 are; messages related to mode settings,
Universal Realtime System Exclusive messages, Data Requests (RQ1), and Data Set (DT1).
●
Universal Non-realtime System Exclusive Messages
❍
Identity Request Message
Status
Data byte
Status
F0H
7EH, dev, 06H, 01H
F7H
Byte
Explanation
FOH
Exclusive status
7EH
ID number (universal non-realtime message)
dev
Device ID (dev: 10H (17) fixed)
06H
Sub ID#1 (General Information)
01H
Sub ID#2 (Identity Request)
F7H
EOX (End Of Exclusive)
*
The “dev” is own device number or 7FH (Broadcast)
VK-88_e.book 102 ページ 2004年4月20日 火曜日 午前9時0分