6-14 HEATER / DRYER TEMPERATURE DOES NOT RISE
NO
CHECK
ACTION
REFERENCE
OUTLINE
1
The media is not loaded
Set up the media
User's Manual
2
Inappropriate temperature
is set on the machine
Check the temperature
setting
User's Manual
When the [PRINT HEATER / DRYER] is [OFF] on the machine,
the Heater does not operate.
3
Media width is too small
Use a wider media
A narrow media may take a long time to heat because it is
subject to be cooled by a suction fan.
4
Environmental temperature
is low
Raise the environmental
temperature
User's Manual
In cold environment, it may take a long time or the Heater may
fail to reach the preset temperature. Suggest using the machine
under the environment from 20 to 32 °C.
5
The voltage of power
supply is unstable
Check the voltage
If the voltage is unstable, the heater cannot function fully.
6
Bad contact or cut line on
the cable between the
Heater Unit and Main
Board
Re-fix / Replace the cable
If the cable between the Heater unit and Main Board is broken,
the Heater temperature does not rise. Check the connection of
the each cable or replace it if it is broken.
7
Fuse on the Power Board
is broken
Replace the Fuse on the
Power Board
The temperature of the Heater does not rise if the Fuse FS1100
or FS1101 is blown out on the Power Board. FS1100 for Print
Heater, FS1101 for Dryer.
8
Power Board is broken
Replace the Power board
The Heater does not work correctly because the signal to the
Heater is not transferred correctly.
6-15 THE TAKE-UP UNIT* DOES NOT OPERATE (*OPTION)
NO
CHECK
ACTION
REFERENCE
OUTLINE
1
The cable for Take-Up Unit
is not connected
Connect the cable to the
machine
2
The media is set up in
[TU2] mode
Select [TU]
User's manual
If the media is set in [TU2] mode, switching operation by
MANUAL or AUTO is not active. When the take-up unit starts
automatic taking up, the switches become active since then.
3
AUTO switch is not ON
Make the setting for the
AUTO switch on
4
Cable is in bad connection
or bad contact
Check the cable
connection / bad contact
Replace the cable
[Section 3 TAKE-UP
BOARD
REPLACEMENT]
(Ref. XJ or LEC series)
Check the connection / bad contact of the cable from AC
Junction Board to SW Power Unit, DC Junction Board, Head
Board, Main Board, TU Junction Board and Take-Up Board.
Replace the cable if there is a problem in the cable itself.
5
Take-Up Board is broken
Replace the Take-Up
Board
[Section 3 TAKE-UP
BOARD
REPLACEMENT]
(Ref. XJ or LEC series)
6-10
Summary of Contents for VS-300
Page 49: ...2 4 MAIN BOARD_Arrangement Diagram Soldering Side ...
Page 60: ...2 15 SERVO BOARD_Arrangement Diagram Soldering Side ...
Page 65: ...2 20 2 4 CARRIAGE BOARD CARRIAGE BOARD_Arrangement Diagram Component Side ...
Page 68: ...2 23 2 5 SUB BOARD SUB BOARD_Arrangement Diagram Component Side ...