CHARGING THE BATTERY
Charging the battery
Plug the power-supply cable
a
into the AC
terminal
b
of the charger and connect it
to the AC supply. The green LED indicates
readiness. All normal AC voltages and fre-
quencies are suitable:
»
100V – 240V AC, 50 Hz – 60 Hz.
The power-supply unit has protective insu-
lation and conforms to the pertinent
EU safety regulations. It comes with a
1.25amp slow-blow fuse. Its outputs (bat-
tery pins, terminals) are protected against
short circuits due to defective batteries
or metallic objects. Battery temperature is
monitored and limited.
Note:
Be sure to prevent bare metallic objects
from entering the battery slot and use the
unit exclusively in a dry environment.
Place battery
8
with its contacts onto the
pins in the charger slot. Rapid charging
will start after about 2 s, and the red LED
glows. Cutoff voltage and battery tem-
perature are monitored during charging.
At the cutoff voltage, the unit switches
to trickle charge. If the battery voltage
exceeds the admissible maximum, the red
LED will go out and rapid charging is inter-
rupted until the temperature is back to
normal.
Trickle charging is in progress when the
green and red LEDs are blinking. This
makes up for the spontaneous discharge
of the battery so that the latter may be left
in the charger over prolonged periods.
Ambient temperature: approx. 5°C to
35°C. The overall duration of the charging
cycle depends on battery condition. After
normal discharge, about one hour or less
is suffi cient.