28
Connect the water supply (see 2.5.). Switch on the drive unit with safety inching
switch (21). For locking, the knob next to the safety switch (21) must be pressed
with the safety switch (21) pressed down. Hold the diamond core drilling crown
by the insulated grip surfaces, move forward slowly with the feed lever (4) and
start tapping carefully with a low water supply. Once the diamond core drilling
crown has engaged all-round, the feed rate can be increased. Adjust the water
pressure to a point where there is a moderate, but constant, fl ow for water from
the bore hole. Insuffi cient water pressure (where the waste material fl ows out
of the bore hole as thick sludge rather than liquid) is as bad for the working
effi ciency and service life of the diamond core drilling crown as is excessive
water pressure, which causes completely clear water to fl ow out. Suck up the
drilling water preferably with a suitable dry and wet vacuum cleaner, e.g.
ROLLER’S Protector L or ROLLER’S Protector M.
WARNING
WARNING
Ensure that no water is allowed to get into the drive unit motor during
operation. DANGER OF FATAL ACCIDENT!
If the drive unit is stopped due to excessive feed pressure, or becomes blocked
as a result of resistance in the drilling gap, the multi-function elec tronic system
reduces the motor current – and thus the turning speed of the drive unit – to a
minimum. The drive unit does not shut down how ever. As the feed pressure is
reduced, the turning speed of the drive unit is increased once more. This
procedure, even if it is repeated several times in succession, prevents damage
to the drive unit. If the motor remains stopped despite the reduction in feed
pressure, the drive unit must be shut down and the diamond core drilling crown
freed manually (see 5.).
WARNING
WARNING
Protector out the mains plug!
ROLLER’S Centro S2/3,5
Fix the ROLLER’S Bohrständer T in one of the ways described in 3.3. Loosen
the two screws (52) on the fl ange of the ROLLER’S Bohrständer T, insert
ROLLER’S Centro S2/3.5 in the guide (53). Hold the drive unit and tighten the
screws (52) Tighten the lock nut. Screw the selected diamond core drilling
crown onto the drive spindle (11) of the drive unit and tighten by hand with a
slight swing. Tightening with an open-ended wrench is not necessary.
Connect the water supply (see 2.5.). Switch on the drive unit with the rocker
switch (21a). Hold the diamond core drilling crown by the insulated grip surfaces,
move forward slowly with the feed lever (4) and start tapping carefully with a
low water supply. The feed can be increased once the diamond core drilling
crown has engaged all round. Set the water pressure so that a moderate but
constant supply of water emerges from the bore hole. Too low water pressure at
which the removed material emerges rather muddily from the bore hole is ,just as
much a disadvantage for the progress of work and useful life of the diamond core
drilling crown as too high water pressure at which the fl ushing water emerges
clearly from the bore hole. Suck up the drilling water preferably with a suitable dry
and wet vacuum cleaner, e.g. ROLLER’S Protector L or ROLLER’S Protector M.
WARNING
WARNING
Ensure that no water is allowed to get into the drive unit motor during
operation. DANGER OF FATAL ACCIDENT!
If the drive unit is stopped due to excessive feed pressure, or becomes blocked
as a result of resistance in the drilling gap, the multi-function elec tronic system
reduces the motor current – and thus the turning speed of the drive unit – to a
minimum. The drive unit does not shut down how ever. As the feed pressure is
reduced, the turning speed of the drive unit is increased once more. This
procedure, even if it is repeated several times in succession, prevents damage
to the drive unit. If the motor remains stopped despite the reduction in feed
pressure, the drive unit must be shut down and the diamond core drilling crown
freed manually (see 5.).
WARNING
WARNING
Protector out the mains plug!
3.6 Removal of the drilling core
NOTICE
NOTICE
When carrying out vertical drilling, e.g. in a ceiling, note that the drilling core
normally drops out as soon as the hole is complete! Take appropriate steps to
ensure that personal injury or material damage does not result.
If the drilling core remains hanging in the diamond core drilling crown after the
core-drilling operation is complete, the bit must be unscrewed from the drive
unit and the drilling core knocked out with a rod.
NOTICE
NOTICE
NEVER hit the casing of the drilling core with a metal item such as a hammer
or wrench in order to loosen the drilling core. This will cause the casing pipe
to become dented, which will make blocking of the drilling core even more likely
on future occasions. The diamond core drilling crown may then be rendered
unusable.
If the core-drilling operation does not penetrate fully, the drilling core can be
broken up, down to a depth of 1.5 x Ø, by inserting a tool such as a chisel into
the drilling gap. If the drilling core cannot be secured, use a tool such as a
hammer drill to make an angled hole into the drilling core, and insert a rod to
extract it.
3.7 Extending the diamond core drilling crown
If the stroke distance of the drill upright, or the useful drilling depth of the diamond
core drilling crown, is insuffi cient, an annular-bit extension ((50) accessory art.
no. 180155) should be used. Start by drilling in as far as possible in the normal
way.
If the stroke distance of the drill upright, and boring depth within the usa ble
boring depth of the diamond core drilling crown, are insuffi cient, proceed as
follows:
WARNING
WARNING
Unplug from the mains power supply! Do not Protector the diamond core
Unplug from the mains power supply!
Unplug from the mains power supply!
drilling crown out of the core-drilling hole. Detach the diamond core drilling
crown from the drive unit (see 2.3.2.). Turn back the drive unit without the
diamond core drilling crown. Fit the annular-bit exten sion ((50) accessory art.
no. 180155) between the diamond core drilling crown and drive unit.
If the usable drilling depth of the diamond-tipped annular core is insuffi cient,
proceed as follows:
WARNING
WARNING
Unplug from the mains power supply! Detach the diamond core drilling
Unplug from the mains power supply!
Unplug from the mains power supply!
crown from the drive unit (see 2.3.2.). Turn back the drive unit without the
diamond core drilling crown. Protector the diamond core drilling crown out of
the core-drilling hole. Break up the drilling core (see 3.6.), and remove it from
the core-drilling hole. Reinsert the diamond core drilling crown into the hole.
Fit the annular-bit extension ((50) accessory art. no. 180155) between the
diamond core drilling crown and drive unit.
4 Maintenance
Notwithstanding the maintenance described below, it is recommended to send
in the power tool to an authorised ROLLER’S contract customer service work-
shop for inspection and periodic testing of electrical devices at least once a
year. In Germany, such periodic testing of electrical devices should be performed
in accordance with DIN VDE 0701-0702 and also prescribed for mobile electrical
equipment according to the accident prevention rules DGUV, regulation 3
"Electrical Systems and Equipment". In addition, the respective national safety
provisions, rules and regulations valid for the application site must be considered
and observed.
4.1 Maintenance
WARNING
WARNING
Protector out the mains plug before maintenance work!
Check the function of the PRCD fault current circuit breaker regularly (see 2.1.).
Keep the drive unit and handles clean. Clean the drill stand and diamond core
drilling crown with water after fi nishing the drilling work. Blow out the air vents
on the motor from time to time. Keep the drilling crown connecting thread on
the drive unit and the connecting thread of the diamond core drilling crown
clean and oil from time to time. Clean plastic parts (e.g. housing) only with a
mild soap and a damp cloth. Do not use household cleaners. These often
contain chemicals which can damage the plastic parts. Never use petrol,
turpentine, thinner or similar products for cleaning.
Make sure that liquids never get onto or inside the electric diamond core drilling
machine. Never immerse the electric diamond core drilling machine in liquid.
4.2 Inspection/Maintenance
WARNING
WARNING
Protector out the mains plug before maintenance and repair work! This
Protector out the mains plug before maintenance and repair work!
Protector out the mains plug before maintenance and repair work!
work may only be performed by qualifi ed personnel.
The gear runs in a life-long grease fi lling and therefore needs no lubrication.
The motors of ROLLER’S Centro S1, ROLLER’S Centro S3, ROLLER’S Centro
S2/3.5, ROLLER’S Centro SR and ROLLER’S Centro DP have carbon brushes.
These are subject to wear and must therefore by checked and changed by
qualifi ed specialists or an authorised ROLLER customer service workshop from
time to time.
eng eng