background image

Translation of the Original Instruction Manual

Fig. 1
1  On/Off switch

2  Suction hose

3  Nozzle for suction hose

4  Suction fi lter

5  High-pressure hose

6  Nozzle for high-pressure hose

7  "Test" shutoff valve

  8  "Pressure" regulating valve

  9  Pressure gauge

10  Suction fi lter with check valve

11  Pressure limit adjusting wheel

12  Connection piece with pressure 

gauge and shutoff valve (accessory)

General power tool safety warnings

WARNING

WARNING

  

Read all safety warnings, instructions, illustrations and specifi cations provided 

with this power tool. Failure to follow all instructions listed below may result in 

electric shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
The term “power tool” in the warnings refers to your mains-operated (corded) power 

tool or battery-operated (cordless) power tool.
1)  Work area safety

a)  Keep work area clean and well lit. Cluttered or dark areas invite accidents.

b)  Do not operate power tools in explosive atmospheres, such as in the pres-

ence of fl ammable liquids, gases or dust. Power tools create sparks which 

may ignite the dust or fumes.

c)  Keep children and bystanders away while operating a power tool. Distrac-

tions can cause you to lose control.

2)  Electrical safety

a)  Power tool plugs must match the outlet. Never modify the plug in any way. 

Do not use any adapter plugs with earthed (grounded) power tools. Unmodi-

fi ed plugs and matching outlets will reduce risk of electric shock.

b) Avoid body contact with earthed or grounded surfaces, such as pipes, 

radiators, ranges and refrigerators. There is an increased risk of electric shock 

if your body is earthed or grounded.

c)  Do not expose power tools to rain or wet conditions. Water entering a power 

tool will increase the risk of electric shock.

d)  Do not abuse the cord. Never use the cord for carrying, pulling or unplug-

ging the power tool. Keep cord away from heat, oil, sharp edges or moving 

parts. Damaged or entangled cords increase the risk of electric shock.

e)  When operating a power tool outdoors, use an extension cord suitable for 

outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock.

f)  If operating a power tool in a damp location is unavoidable, use a residual 

current device (RCD) protected supply. Use of an RCD reduces the risk of 

electric shock.

3)  Personal safety

a)  Stay alert, watch what you are doing and use common sense when oper-

ating a power tool. Do not use a power tool while you are tired or under 

the infl uence of drugs, alcohol or medication. A moment of inattention while 

operating power tools may result in serious personal injury.

b) Use personal protective equipment. Always wear eye protection. Protec-

tive equipment such as a dust mask, non-skid safety shoes, hard hat or hearing 

protection used for appropriate conditions will reduce personal injuries.

c)  Prevent unintentional starting. Ensure the switch is in the off-position before 

connecting to power source and/or battery pack, picking up or carrying the 

tool. Carrying power tools with your fi nger on the switch or energising power 

tools that have the switch on invites accidents.

d)  Remove any adjusting key or wrench before turning the power tool on. 

wrench or a key left attached to a rotating part of the power tool may result in 

personal injury.

e)  Do not overreach. Keep proper footing and balance at all times. This enables 

better control of the power tool in unexpected situations.

f)  Dress properly. Do not wear loose clothing or jewellery. Keep your hair and 

clothing away from moving parts. Loose clothes, jewellery or long hair can be 

caught in moving parts.

g) If devices are provided for the connection of dust extraction and collec-

tion facilities, ensure these are connected and properly used. Use of dust 

collection can reduce dust-related hazards.

h)  Do not let familiarity gained from frequent use of tools allow you to become 

complacent and ignore tool safety principles. A careless action can cause 

severe injury within a fraction of a second.

4)  Power tool use and care

a)  Do not force the power tool. Use the correct power tool for your application. 

The correct power tool will do the job better and safer at the rate for which it was 

designed.

b)  Do not use the power tool if the switch does not turn it on and off. Any power 

tool that cannot be controlled with the switch is dangerous and must be repaired.

c)  Disconnect the plug from the power source and/or remove the battery pack, 

if detachable, from the power tool before making any adjustments, changing 

accessories, or storing power tools. Such preventive safety measures reduce 

the risk of starting the power tool accidentally.

d)  Store idle power tools out of the reach of children and do not allow persons 

unfamiliar with the power tool or these instructions to operate the power 

tool. Power tools are dangerous in the hands of untrained users.

e)  Maintain power tools and accessories. Check for misalignment or binding 

of moving parts, breakage of parts and any other condition that may affect 

the power tool’s operation. If damaged, have the power tool repaired before 

use. Many accidents are caused by poorly maintained power tools.

f)  Keep cutting tools sharp and clean. Properly maintained cutting tools with 

sharp cutting edges are less likely to bind and are easier to control.

g)  Use the power tool, accessories and tool bits etc. in accordance with these 

instructions, taking into account the working conditions and the work to be 

performed. Use of the power tool for operations different from those intended 

could result in a hazardous situation.

h)  Keep handles and grasping surfaces dry, clean and free from oil and grease. 

Slippery handles and grasping surfaces do not allow for safe handling and control 

of the tool in unexpected situations.

5) Service

a)  Have your power tool serviced by a qualifi ed repair person using only 

identical replacement parts. This will ensure that the safety of the power tool 

is maintained.

Safety instructions for electric pressure testing pump

WARNING

WARNING

Only connect the electrical device of protection class I to a socket/extension 

lead with a functioning protective contact. There is a danger of electric shock.

The electrical device develops a very high pressure of up to 6 MPa (60 bar, 

870 psi). So be very careful. Keep third parties away from the work area when 

working with the electrical device.

● 

Do not use the electrical device if it is damaged. There is a danger of accident.

● 

Examine the high-pressure hose for damage very time before using. Damaged 

high-pressure hoses can burst and cause injury.

● 

Only use original high-pressure hoses, fi ttings and couplings for the elec-

trical device. This ensures that the safety of the device is maintained.

● 

Apply the electrical device horizontally and dry for operation. Penetration 

of water into the electrical device increases the risk of electric shock.

● 

Do not aim liquid jets at the electrical device, not even for cleaning. Pene-

tration of water into the electrical device increases the risk of electric shock.

● 

Do not suck up infl ammable or explosive liquids, for example petrol, oil, alcohol, 

solvent, with the electrical device. The fumes or liquids can ignite or explode.

● 

Do not operate the device in rooms where there is a risk of explosion. The 

fumes or liquids can ignite or explode.

● 

Protect the electrical device against frost. The device could be damaged. Let 

the electrical device  run empty for about 1 minute, if necessary, to drain off 

remaining water.

● 

Never let the electrical device operated unattended. Switch the electrical 

device off at the On/Off switch (1) and pull out the mains plug for longer 

work breaks. Electrical devices can cause hazards which lead to material damage 

or injury when left unattended. 

● 

Do not operate the electrical device for long periods on a closed sanitary 

or heating system or with closed "Test" shutoff valve (7). The electrical device 

could be damaged by overheating.

The electrical device is not intended/suitable for permanent connection to 

the installation. Disconnect all hoses from the installation after completing 

the work. Electrical devices can cause hazards which lead to material damage 

or injury when left unattended. 

● 

Children and persons who, due to their physical, sensory or mental abilities 

or lack of experience and knowledge are unable to operate the electrical 

device safely may not use this electrical device without supervision or 

instruction by a responsible person. Otherwise there is a risk of operating 

errors and injuries.

● 

Only allow trained persons to use the electrical device. Apprentices may only 

operate the electrical device when they are older than 16, when this is necessary 

for their training and under the supervision of a trained operative.

● 

Check the power cable of the power tool and extension leads regularly for 

damage. Have these renewed by qualifi ed experts or an authorised ROLLER 

customer service workshop in case of damage.

● 

Only use approved and appropriate marked extension leads with a suffi cient 

cable cross-section at least with the protection class approved in 1.4. 

Electrical data. Use extension leads up to a length of 10 m with cable cross-

section 1.5 mm², from 10 – 30 m with cable cross-section 2.5 mm².

The mains connection must be made by a qualifi ed electrician according 

to valid regulations. It is recommended to connect this machine to a power 

supply which either has a residual current device (RCD) which cuts off the 

power supply as soon as the leakage current to earth exceeds 30 mA for 

30 ms or an  earth tester.

Explanation of symbols

WARNING

WARNING

  Danger with a medium degree of risk which could result in 

death or severe injury (irreversible) if not heeded.

CAUTION

CAUTION    

Danger with a low degree of risk which could result in minor 

injury (reversible) if not heeded.

NOTICE

NOTICE

 

Material damage, no safety note! No danger of injury.

   

Read the operating manual before starting

   

Use eye protection

eng eng

7

Summary of Contents for E-Control 2

Page 1: ...etriebsanleitung deu Betriebsanleitung deu Betriebsanleitung 3 eng Instruction Manual eng Instruction Manual eng Instruction Manual 7 fra Notice d utilisation 11 ita Istruzioni d uso 15 nld Handleidin...

Page 2: ...Fig 1 12 1 9 7 6 2 10 5 11 8 4 3...

Page 3: ...ind diese anzuschlie en und richtig zu verwenden Verwendung einer Staubabsaugung kann Gef hrdungen durch Staub verringern h Wiegen Sie sich nicht in falscher Sicherheit und setzen Sie sich nicht ber d...

Page 4: ...Wert der Fl ssigkeiten 6 5 9 5 Viskosit t der Fl ssigkeiten 1 5 mPa s Selbstansaugende Pumpe 500 mm 1 4 Elektrische Daten 230 V 50 Hz 1 300 W 6 A 110 V 50 Hz 1 300 W 13 A Schutzklasse I Schutzart IP 2...

Page 5: ...alen Sicherheitsbe stimmungen Regeln und Vorschriften zu beachten und zu befolgen 4 1 Wartung WARNUNG WARNUNG Vor Inspektion Netzstecker ziehen ZumAbbau von anstehendem DruckAbsperrventil Test 7 und D...

Page 6: ...tra e 4 71332 Waiblingen Deutschland Die gesetzlichen Rechte des Verwenders insbesondere seine Gew hrleistungsanspr che bei M ngeln gegen ber dem Verk ufer sowie Anspr che aufgrund vors tzlicher Pflic...

Page 7: ...Maintain power tools and accessories Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the power tool s operation If damaged have the power t...

Page 8: ...to the left press in the pressure limit adjusting wheel 11 and set to the desired step 2 3 Suction hose Screw the suction hose 2 to the suction hose nozzle 3 Do not kink the suction hose Only pump cle...

Page 9: ...plug before carrying out maintenance or repair work This work may only be performed by quali ed personnel Open the Test shutoff valve 7 and Pressure regulating valve 8 to release pressure The residual...

Page 10: ...purpose by ROLLER Complaints will only be accepted if the product is returned to a customer service station authorized by ROLLER without prior interference and in a fully assembled condition Replaced...

Page 11: ...l habitude de l utiliser Une fraction de seconde d inattention peut provoquer une blessure grave 4 Utilisation et entretien de l outil lectrique a Ne pas forcer l outil lectrique Utiliser l outil lec...

Page 12: ...1 5 Dimensions 395 270 295 mm 15 6 10 6 11 6 1 6 Poids 10 kg 22 lb 1 7 Bruit missions au poste de travail LPA 74 dB A LWA 86 dB A K 3 dB A Norme d valuation de la mesure DIN EN 60335 2 79 2016 Norme d...

Page 13: ...ipements lectriques mobiles conform ment aux prescrip tions de pr vention des accidents DGUV 3 relatives aux installations et aux quipements lectriques En outre les prescriptions de s curit directives...

Page 14: ...ngen Deutschland Cette garantie ne modi e pas les droits juridiques de l utilisateur en particulier son droit des prestations de garantie du revendeur en cas de d fauts ainsi que ses droits r sultant...

Page 15: ...i lesioni entro una frazione di secondo 4 Utilizzo e trattamento dell elettroutensile a Non sovraccaricare l elettroutensile Utilizzare l elettroutensile adatto per il tipo di lavoro speci co Con l el...

Page 16: ...Collegamento elettrico AVVERTIMENTO AVVERTIMENTO Attenzione alla tensione di rete Prima di allacciare la pompa elettrica Attenzione alla tensione di rete Prima di allacciare la pompa elettrica Attenzi...

Page 17: ...e la valvola di arresto Test 7 e la valvola di regolazione della pressione Pressure 8 In caso contrario nel corso dello smontaggio la pressione residua potrebbe rappresentare un rischio di lesioni per...

Page 18: ...eve essere inviato al SERVICE CENTER Neue Rommelshauser Stra e 4 71332 Waiblingen Deutschland I diritti legali dell utilizzatore in particolare i diritti di garanzia in caso di vizi nei confronti del...

Page 19: ...worden Gebruik van een stofafzuiging kan risico s door stof verminderen h Let op dat u zich niet ten onrechte veilig voelt en negeer nooit de veilig heidsregels voor elektrisch gereedschap ook niet w...

Page 20: ...role EN ISO 4871 2009 2 Inbedrijfstelling LET OP LET OP ROLLER S E Control 2 is niet voor permanente aansluiting op de installatie ROLLER S E Control 2 is niet voor permanente aansluiting op de instal...

Page 21: ...rische installaties en bedrijfsmiddelen ook voor mobiele elektrische bedrijfsmiddelen voorgeschreven Daarnaast dienen de voor de plaats van inzet geldende nationale veiligheids bepalingen regels en vo...

Page 22: ...ent het product te worden ingeleverd bij het SERVICE CENTER Neue Rommelshauser Stra e 4 71332 Waiblingen Deutschland De wettelijke rechten van de gebruiker met name de garantierechten tegenover de ver...

Page 23: ...tt elverktyget startas oavsiktligt d F rvara elverktyg som inte anv nds utom r ckh ll f r barn L t inte personer som inte k nner till hur elverktyget fungerar eller som inte har l st dessa anvisningar...

Page 24: ...ingssystem st ller in inst llningshjulet Tryckbegr nsning 11 p tryckniv 1 P s s tt f rhindras en o nskad verbelastning av r rledningssystemet Endast i speciella fall d ett h gt provtryck kr vs kan de...

Page 25: ...e produkter f r reng ring Se till att v tskor aldrig hamnar p eller tr nger in i den elektriska provtryck ningspumpens inre Doppa aldrig den elektriska provtryckningspumpen i v tska 4 2 Inspektion rep...

Page 26: ...ROLLER kundtj nstver kstad Reklamationer accepteras endast om produkten l mnas till en auktori serad ROLLER kundtj nstverkstad utan att ingrepp gjorts och utan att den dessf rinnan tagits is r Bytta p...

Page 27: ...et ud af stikkontakten og eller fjern det udtagelige genopladelige batteri inden du foretager indstillinger p apparatet skifter indsatsv rk t jsdele eller l gger el v rkt jet fra dig Denne forholdsreg...

Page 28: ...nbefales det at indstille stillehjulet trykbegr nsning 11 p tryktrin 1 S undg s en u nsket overbelastning af r rledningssystemet De h jere tryktrin v lges b r kun blive valgt i s rlige tilf lde hvor d...

Page 29: ...p eller i den elektriske trykpr vepumpes indre S nk aldrig den elektriske trykpr vepumpe ned i v sker 4 2 Inspektion istands ttelse ADVARSEL ADVARSEL Tr k stikket ud af stikkontakten inden vedligehold...

Page 30: ...seret ROLLER kundeservicev rksted Reklamationer vil kun blive anerkendt hvis produktet indsendes til et autoriseret ROLLER kundeservicev rksted uden forudg ende indgreb i ikke splittet tilstand Udskif...

Page 31: ...a kokemattomien henkil iden k yt ss e Hoida s hk ty kaluja ja vaihtoty kaluja huolellisesti Tarkista ett liikkuvat osat toimivat moitteettomasti ja juuttumatta ja ettei osia ole rikkoutunut tai vaurio...

Page 32: ...a putkijohtoj rjestelm tai tarkastettavaa s ili t Paineens t venttiili Pressure 8 voidaan s t etuk teen paineenrajoituksen s timell 11 vaiheittain 6 ssa n 0 5 6 MPa n 5 60 bar 73 870 psi painevaiheess...

Page 33: ...iedolla saippualla ja kostealla liinalla l k yt kodin puhdistusai neita Ne sis lt v t usein kemikaaleja jotka saattavat vahingoittaa muoviosia l k yt puhdistukseen miss n tapauksessa bensiini t rp tti...

Page 34: ...sopimuskorjaamot Reklamaatiot hyv ksyt n ainoastaan siin tapauksessa ett tuote j tet n valtuutettuun ROLLER sopimuskorjaamoon ilman ett sit on yritetty itse korjata tai muuttaa tai purkaa osiin Vaihd...

Page 35: ...i ali izklopiti je nevarno in ga je potrebno popraviti c Pred nastavitvijo naprave menjavo delov vstavnega orodja ali odlo itvijo elek tri nega orodja morate povle i vti iz vti nice in ali odstraniti...

Page 36: ...tavitev tlaka Pressure 8 z zasukom na levo Previsoko nastavljen tlak bi lahko po kodoval cevovodni sistem oz posodo ki jo je treba preizkusiti Ventil za nastavitev tlaka Pressure 8 lahko prednastavite...

Page 37: ...jajte Pred vsako uporabo preverite visokotla ne in sesalne gibke cevi glede po kodb Ne uporabljajte po kodovanih gibkih cevi Komponenteizumetnemase naprimerohi je istiteizklju no t izdelka140119 ali z...

Page 38: ...delavnici ROLLER Reklamacije se priznajo samo v primeru e se proizvod v nerazstavljenem stanju dostavi v poobla eno pogodbeno servisno delavnico ROLLER ne da bi bili prej opravljeni kakr ni koli pose...

Page 39: ...39...

Page 40: ...disposizioni delle direttive 2006 42 EC 2009 127 EC 2014 30 EC 2011 65 EC 2015 863 EC nld EG conformiteitsverklaring Wij verklaren op eigen verantwoordelijkheid dat het onder Technische gegevens besc...