Gas category table, according to the country of destination of the appliance.
Injector N°
Gas
Pressures
Diameter
Injector n°1
G30 / G31
Butane/Propane
28
-
30/37
90/100
Injector n°2
G30 / G31
Butane/Propane
50
85/100
Injector n°3
G20 / G25
Natural Gas
20
-
25
135/100
Injector n°4
G25
Natural Gas
25
140/100
Injector n°5
G25
Natural gas
20
150/100
Injector n°6
G31
Propane
50
85/100
Country of destination
Category
Gas
Pressures
Diameter of
injector
France/Luxembourg
II2E+3+
II2E+3B/P
G20/G25
G30/G31
G20/G25
G30/G31
20/25
28
-
30/37
20/25
50
135
90
135
85
Germany
II2E3B/P
G20
G25
G30/G31
20
20
50
135
150
85
Austria
II2H3B/P
G20
G30/G31
20
50
135
85
Belgium
I3+
I2E
G30/G31
G20/G25
28
-
30/37
20/25
90
135
Sweden, Denmark,
Finland
II2H3B/P
G20
G30/G31
20
30
135
90
Spain
II2H3+
II2H3P
G20
G30/G31
G20
G31
20
28
-
30/37
20
50
135
90
135
85
Netherlands
II2L3B/P
II2L3P
G25
G30/G31
G25
G31
25
30
25
50
140
90
140
85
Norway
I3B/P
G30/G31
30
90
Iceland/Greece/United
Kingdom/Italy/Portugal
II2H3+
G20
G30/G31
20
28
-
30/37
135
90
Poland
II2E3P
G20/25
G31
20
37
135
90
18
Summary of Contents for PSR 400 G
Page 2: ......
Page 3: ......
Page 22: ...22 Nomenclature PSR 400 G Spare parts PSR 400 G...
Page 23: ...23...
Page 24: ...24 Nomenclature PSR 600 G Spare parts PSR 600 G...
Page 25: ...25...
Page 26: ...Nomenclature PSR 900 G Spare parts PSR 900 G 26...
Page 27: ...27...
Page 28: ...G03232...