Rollerdor RD20X2ANSA Control Box, Edition 2022/1
1
Operation: The unit will automatically arm on closure, a break in alarm signal is triggered if the button rail
is forced open.
2
Alarm LED status: the alarm has a LED status LED light, if the light is GREEN then the door is closed and the
alarm is set; if the LED is RED the door is open and the alarm is off; if the LED is flashing then the door is in
motion or is part open.
3
Activation: Should the alarm be activated it will continue the alarm until either the handset is operated to
reset the alarm or it will automatically reset after 15 minutes.
ALARM SYSTEM
MR
1
Open the door fully, remove the connection going into STOP terminal on the main board
(fig.5 / fig.6)
, the
LED next to Status should turn from GREEN to RED, then turn the power off.
2
Press and hold the Door Run button on the board
(fig.16)
, whilst holding this button down turn the power
on, the RED LED on the box should slowly flash off and on
(fig.13)
.
3
Re-insert the connection into the STOP terminal on the main board
(fig.5 / fig.6)
, the Status LED should
turn back to green.
4
Turn power off and leave for 10 seconds then turn power back on, reset is now complete.
FACTORY RESET
B
A
Pictures are for illustration purposes only, connector blocks are not provided and further fittings may be required.