4. OPTIONAL EXTRAS
Pictures are for illustration purposes only, connector blocks are not provided and further fittings may be required.
WIRING AS FOLLOWS:
Grey 11 Terminal Block on right hand side
(fig.17)
:
Switches work on a sequential action so from an initial
position of door closed it will be the following cycle:
(open, stop, close, stop, open etc)
.
IMP - UP & DOWN Wire.
COM - Common wire from supply to switch.
Rocker Switch
(fig.18)
:
4
– Up wire
3
– Down wire from rocker switch
5
– Common wire for the supply to the switch
Fit Link wire from
5 to 2
To open rocker switch remove screws
Key Switch
(fig.19)
:
Right Block 13
– Up wire
Left Block 14
– Down wire
Right Block 14
– Common wire for the supply to the switch
Left Block 13
– Right Block 14 Link wire between terminals
To open key switch remove screw then turn key
a quarter turn.
HARD WIRED ROCKER / KEY SWITCH
fig.19B
fig.19A
fig.18
fig.17
Link wire
Up wire
Down wire
Common wire