Part No 4801-5162 Rev 09-2019
RS-500/600 M Series Doors
Page 20
9.5
Attachment Points of Door
When sizing the clear opening for attachment of the door, pay close attention to the following guidelines. Door flanges
have pre-drilled holes that serve as mounting points of door.
Flange widths are shown in
1. Make sure that door assembly is plumb & square.
2. The top unit has a top flange and a bottom flange. Make sure these flanges overlap framing.
3. The vertical members have inner flanges and outer flanges. The inner and outer flanges have pre-drilled holes
that serve as attachment points. Make sure the outer flanges overlap framing.
4. When door is raised in front of clear opening (
), Diagram flanges must be flush against
framing for attachment of screws
Diagram 9A
Bottom View
Framing Members