Part No 4801-5162 Rev 09-2019
RS-500/600 M Series Doors
Page 31
14.6
Preparation for Operation
Refer of the RollSeal SC-325M and SC-650M Controller Manual (4801-5161) for more information on
Controller Settings.
Note: If you detect any problems, STOP. Disconnect electrical power. Contact your
distributor for assistance.
1.
Apply 115VAC power to Control and turn Control toggle switch on.
2.
Set the Open and Close Limits:
1.
Depress the
Mode
button (●) for at least 5 seconds. P1 (Close Time Delay) will be then be displayed
in the Display Indicator.
2.
Depress and release the
Mode
button until PS1 (Change Program Limits) is displayed.
3.
Depress
Up
(
) until “yes” is displayed.
4.
Depress the
Mode
button again (●). PS2 (Set Open Limit) will be displayed.
5.
The door will proceed to the open limit and then stop. Once the door stops, adjust open limit using
the
Up
(
) or
Down
(
) buttons until open limit is satisfactory.
6.
Depress the
Mode
button (●) again. PS3 (Set Closed Limit) will be displayed.
7.
The door will proceed to the closed limit and then stop. Once door stops, adjust this limit using the
Up
(
) or
Down
(
) buttons until the close limit is satisfactory.
8.
Depress the
Mode
button (●) again and the controller will exit the programming mode and return to
displaying the actual position.
3.
Press “Open” button on Outside Switch. If the Door is set to automatically close, door will time out and
automatically close if safety beams are clear. If the Door is set to manually close, press “Close” button
on Outside Switch and door should close.
4.
Press “Open” (and “Close” if required) a couple times to insure proper operation.
5.
Repeat steps 4 and 5 for Inside Switch.
6.
Verify Safety Beams reverse door when blocked during closing.
7.
Verify Leading Edge Switch is operational.
8.
Verify that the Door Movement LED’s and Egress Buzzer (if applicable) are functioning properly.
9.
Ensure Safety Pull Hook for Egress and Pull Hook Tether are mounted inside cooler and Manual Crank
Handle for motor is mounted outside.
The door is now ready for operation.