Part No 4801-5162 Rev 09-2019
RS-500/600 M Series Doors
Page 41
NOTE: The Release for the
Cam Buckle is located on
the panel side of the
Buckle. This view shows
the Cam Buckle as see
from the front of the door.
24.3
Resetting (Closing) The Door
After the RollSeal RS-500/600 Door is opened by using the Emergency Egress Strap, the door must be carefully
re-set to ensure proper operation in the future.
1.
Firmly hold strap. See
2.
Press the Cam Buckle Release. See
3.
Gradually feed strap through Cam Buckle until door is closed at bottom and D-ring is in the position
shown in
4.
Return Emergency Egress Tool to retainer for future use.
5.
Cycle the door up and down in normal operating mode to ensure proper re-setting of the door. Adjust
if necessary. Door should now function normally.
Diagram 24E
25
CAUTION!
When the Cam Buckle is released, the door will rapidly close unless tension is held on the strap.
Keep fingers away from buckle while closing.
!
Firmly
hold
strap.
Cam
Buckle
Egress
Strap
D-ring
Egress
Tool
Cam Buckle
Release
NOTE: This view
shows the Cam
Buckle as seen
from the back of
the door when the
Egress Strap has