4.
Grab and hold the PIM plate assembly and floating in a manner that will prevent the floating material from coming
off of the PIM bolts. Re-install the PIM plate assembly in the track starting with the top PIM bolt. Align the PIM
bolts with the holes in the track (
Diagram 26G
). Firmly press the PIM bolts into their associated holes and attach
the PIM nuts to the PIM bolts but do not tighten until all bolts have been installed. After all of the PIM bolts have
been installed, tighten the nuts pulling the PIM plate firmly against the track. (
Diagram 26G
)
NOTE: Doors with a CMS unit have floating that requires slots to be cut in it to match the slots in the metal
PIM plate. Use a razor knife to cut the fabric out of the slots. (Diagram 34J)
Diagram 26G
Diagram 26H
Warning!
Do not over tighten!
Note: NSF Certified doors are equipped with a black rubber boot that covers the
PIM bolts. Replace the black rubber boots on the PIM bolts that were
removed in Step 4.
Squeeze the
floating around
the PIM Plate
and push the top
in the track
assembly first.
Align all PIM
bolts with holes
in the track
assembly
!
After all of the
PIM bolts have
been installed,
tighten the nuts
pulling the PIM
plate firmly
against the track