9.8
Infrared Sensor Connectors
Located at the bottom of each vertical member is an infrared detector. The detector on each vertical member
operates as a safety device if the infrared beam is interrupted. Door can be set to stop if beams are broken while
closing or to stop and reverse to the full open position. Refer to the RollSeal SC-325M and SC-650M Controller
Manual for more information.
1. Locate female connector on vertical member. This connector is attached to the infrared detector.
2. Locate male connector on horizontal member. Unroll cable until connectors meet.
Pull enough slack to
create a service loop, such that connectors can be pulled out of tracks for photo eye replacement and
troubleshooting purposes.
3. Plug connectors together. Make sure connectors interlock.
4. Repeat for both infrared detectors.
5. Cable ties and adhesive mounts are supplied to secure wire to the inside of tracks.
Diagram 9E
9.9
Fastening Door Assembly to Clear Opening
Diagram 9F
1. Use a tape measure and make sure that the overall height
and overall width of the clear opening meet the door
requirements.
Reference appropriate Table 1-4
2. Make sure that door assembly is plumb & square.
See
3. Center door assembly on clear opening. Align the bottom
of each vertical member with the respective framing board
or posts of the clear opening.
NOTE: For each vertical member, unroll respective sensor
cable attached to horizontal member until cable
reaches the sensor connector attached to the
vertical member.
NOTE: Pull Enough Slack To Leave A Service Loop
For Photo Eye Replacement And
Troubleshooting Purposes