Operation of RS-500/600 Series Doors
NOTE: Refer to the RollSeal SC-325M/650M Controller
Manual for wiring and initial setup. After
wiring the controller to the door, connect
electrical power to the controller. The door is
now ready for operation.
The controller keeps track of the "open" and "closed" positions of the door by means of a mechanical encoder wheel
that is located in the encoder box. The controller electronically counts steps as the wheel turns to keep track of the door
position. The door seals by means of 'hook & loop’ or ‘magnetic’ strips along the edges of the door curtain and vertical
members.
15.1
Operation of a Standard RS-500/600 Series Door:
1.
Depress “Open” switch button mounted on the wall. Door curtain will roll up to 'open' position and find
“HOME” position and drop some to the set upper limit. If door was wired for “timer” it will count down from
set delay and close on its own. If not wired on “timed” function proceed to step 2 to close.
2.
Depress “Close” switch button. Door curtain will roll down to 'closed' position of lower limit and stay
3.
Depress button to open or close door as desired.
4.
Open and close the door a few times to test door operation and remove any wrinkles in the door curtain.
If you detect any problems,
STOP.
Disconnect electrical power.
Contact your distributor for
assistance.