Part No 4801-5162 Rev 09-2019
RS-500/600 M Series Doors
Page 33
15.2
Operation of RS-500/600 Series Door with
Optional CMS Kit
1.
Depress “Open” switch button mounted on the wall.
Door curtain will roll up to 'open' position and find “HOME”
position and drop some to the set upper limit. If door was wired for “timer” it will count down from set delay
and close on its own. If not wired on “timed” function proceed to step 2 to close.
2.
Depress “Close” switch button. Door curtain will roll down to 'closed' position of lower limit and stay
3.
Depress button to open or close door as desired.
4.
Open and close the door a few times to test door operation and remove any wrinkles in the door curtain.
*Refer to the 4801-5161 SC-325M and SC-650M product manual for additional smart controller information.
PROGRAM PARAMETERS
P1
- Close Time Delay (Seconds)
P3
- Deceleration Range
P4
– Warning Output Function
P7
- Refresh Door Limits
P10
- Service Cycle Reset
P11
- Service Reminder (Cycles x 100)
P12
-
Input Status
P20
– Open Input Function
P21
– Input switch Response
P22
– Auxiliary Safety Response
P23
– Encoder Operation
P24
– CMS Output Function
P25
– CMS On Time (Minutes)
P26
– CMS Off Time (Minutes)
PS1
- Set Limits?
PS2
- Set Open Limit
PS3
- Set Close Limit
16
Home Switch and Lead Edge Switch
There are two switches located within the horizontal member mechanism. See
. These switches are
attached to levers that contact the curtain.
The
Home
Switch
establishes
the 'open' reference position
of the door curtain. This
creates the zero reference
position, from which the
encoder counts the position of
the door.
The
Leading Edge Switch
is a
switch that stops the curtain in
the event of a doorway
obstruction.
NSF Certified Doors are equipped
with Left mount Brother operators,
Smart Controller, and Magnetic
Track Sealing System