Safety Instructions
To avoid an electric shock or injury, read and follow the instructions. If at all unsure seek advice
from a suitably competent and qualifies person before use. Retain instructions for future reference.
• Check the meter and leads before use, if damaged do not use. Ensure insulation around leads
and connectors are not damaged. This product has no serviceable parts
• Do not use in area where there is flammable vapour or gas
• Do not use above the marked voltages
• When measuring current, turn off the circuit before using the meter
• Keep fingers behind the fingers guards on the probes and remove probes before replacing the
battery. Do not use without the battery cover. Replace battery when the low battery indicator
appear
• Connect the common test lead before the live test lead, when disconnecting, disconnect the
live lead first
• Caution when working above 30V AC, 42V peak or 60V DC as these pose a shock hazard.
Do not measure voltages above 500V in category 1 installations
I.
INTRODUCTION:
1. Switch
Our DMM adopt rotational switch which situated at the middle of the front case.
It is used for the selection of FUNCTION, RANGE AND POWER ON - OFF.
In order to save energy, please turn the switch to “OFF” position when not in use.
2. Display
3 12mm Height LCD Display.
3. “COM” Jack
Common Jack
4. “V
Ω
mA” Jack
Voltage, resistance, no more than 200Ma,
current and battery input test jack,
50Hz sine wave output jack.
5. “10A” Jack
For the input of more than 200mA current
II.
FEATURES:
Display: 3 LCD With Maximum Display 1999.
Polarity: Auto Polarization
Overrange: Maximum Display “1”
Working Environment: Temp. 0 - 40˚C Relative
Storing Environment: - 15 - 50˚C
Battery: 9V
High Voltage Symbol: DC 1000V or AC 750V range will show high voltage symbol ”HV”
Low Voltage Indication: Left side of LCD will show
or BAT symbol.
Weight: 126g Not Include Battery
III.
TECHNICAL SPECIFICATION:
Accuracy: +a% R No. Of Digits
Guaranteed For 1 Year.
Environmental Temperature: 23˚C + 5˚C
Relative Humidity:
<
75%
- 1 -
Range
200mv
Resolution
100uv
Accuracy
±
0.5% of Rdg
±
2 Digit
- 2 -
2mV
1mV
20mV
10mV
200V 100mV
1000V
Input impedance: 1M
Overload protection: DC or AC peak value of 1000V.
2. DC Current:
1. DC Voltage:
RANGE
RESOLUTION
ACCURACY
200uA
100nA
1uA
10uA
100uA
10mA
100mV
1V
2000uA
20mA
±
1% of rdg
±
2D
±
1.2% of rdg
±
2D
±
2% of rdg
±
2D
200mA
10A
Overload protection: 02A/250V fused 10 A range not fused.
3. AC Voltage:
RANGE
RESOLUTION
ACCURACY
200V
1000V
±
1.2% of rdg
±
10D
Frequcucy range: 45Hz to 400Hz
Overload protection: AC 750V rms
Indication:Average value(rms of sine wave.)
4. Resistance:
RANGE
RESOLUTION
ACCURACY
200
Ω
2000
Ω
20K
Ω
200K
Ω
2000K
Ω
100m
Ω
1
Ω
10
Ω
100
Ω
1K
Ω
±
0.8% of rdg
±
20D
Overload protection: 250VDC or AC rms.Less than 10 sec.
Maximum open circuit voltage: 2.8V
5. Transistor hFE:
Vce approximately 2.8V,1b approximately 10A.
Display show approximately hFE 0-1000.
6. Dlode and Audible Continulty:
Diode: Testing voltage approx. 2.4V, current 1.5Ma. indicate forward diode approx. value.
Buzzer: Sounds when measure less than 70 ± 20.
7. Battery Test:
RANGE
CURRENT CONSUNED
1.5V
9V
50mA
5mA
±
0.8% of rdg
±
3 Digit
1V
DC Volt
Selection
Area
OHM
Selection
Area
AC Volt
Selection
Area
Switch
DC Amp
Selection
Area
Transistor
Selection
Area
10A Jack
Transistor
/hFE Jack
Com Jack
Diode
Selection
Area
“V
Ω
mA”
Jack