background image

Thanks for buying our product. Please go through the instruction manual before starting to use
the meter.

Safety Instructions

To avoid an electric shock or injury, read and follow the instructions. If at all unsure seek advice
from a suitably competent and qualifies person before use. Retain instructions for future reference.
•  Check the meter and leads before use, if damaged do not use. Ensure insulation around leads
    and connectors are not damaged. This product has no serviceable parts
•  Do not use in area where there is flammable vapour or gas
•  Do not use above the marked voltages
•  When measuring current, turn off the circuit before using the meter
•  Keep fingers behind the fingers guards on the probes and remove probes before replacing the
    battery. Do not use without the battery cover. Replace battery when the low battery indicator
    appear
•  Connect the common test lead before the live test lead, when disconnecting, disconnect the
    live lead first
•  Caution when working above 30V AC, 42V peak or 60V DC as these pose a shock hazard.
    Do not measure voltages above 500V in category 1 installations

I. 

INTRODUCTION:

1. Switch
Our DMM adopt rotational switch which situated at the middle of the front case.
It is used for the selection of FUNCTION, RANGE AND POWER ON - OFF. 
In order to save energy, please turn the switch to “OFF” position when not in use.
2. Display
3 12mm Height LCD Display.
3. “COM” Jack
Common Jack
4. “V

mA” Jack

Voltage, resistance, no more than 200Ma,
current and battery input test jack,
50Hz sine wave output jack.
5. “10A” Jack
For the input of more than 200mA current

II. 

FEATURES:

Display: 3 LCD With Maximum Display 1999.
Polarity: Auto Polarization
Overrange: Maximum Display “1”
Working Environment: Temp. 0 - 40˚C Relative
Storing Environment: - 15 - 50˚C
Battery: 9V
High Voltage Symbol: DC 1000V or AC 750V range will show high voltage symbol ”HV”
Low Voltage Indication: Left side of LCD will show 

      

or BAT symbol.

Weight: 126g Not Include Battery

III. 

TECHNICAL SPECIFICATION:

Accuracy: +a% R No. Of Digits
Guaranteed For 1 Year.
Environmental Temperature: 23˚C + 5˚C
Relative Humidity: 

<

75%

- 1 -

Range
200mv

Resolution
100uv

Accuracy

±

0.5% of Rdg 

±

2 Digit

- 2 -

2mV 

1mV 

20mV 

10mV 

200V                             100mV 
1000V 

Input impedance: 1M 

Overload protection: DC or AC peak value of 1000V.
2. DC Current:

1. DC Voltage: 

 

   

 

RANGE 

RESOLUTION 

ACCURACY 

200uA

100nA
1uA
10uA
100uA
10mA 

100mV
1V

2000uA
20mA

±

1% of rdg 

±

2D

±

1.2% of rdg 

±

2D

±

2% of rdg 

±

2D

200mA
10A

Overload protection: 02A/250V fused 10 A range not fused.

3. AC Voltage:

 

RANGE 

RESOLUTION 

ACCURACY 

200V
1000V

±

1.2% of rdg 

±

10D 

Frequcucy range: 45Hz to 400Hz

Overload protection: AC 750V rms

Indication:Average value(rms of sine wave.)
4. Resistance:

 

RANGE 

RESOLUTION 

ACCURACY 

200

Ω

2000

Ω

20K

Ω

200K

Ω

2000K

Ω

100m

Ω

1

Ω

10

Ω

100

Ω

1K

Ω

±

0.8% of rdg 

±

20D 

Overload protection: 250VDC or AC rms.Less than 10 sec.

Maximum open circuit voltage: 2.8V
5. Transistor hFE:

Vce approximately 2.8V,1b approximately 10A.

Display show approximately hFE 0-1000.
6. Dlode and Audible Continulty:

Diode: Testing voltage approx. 2.4V, current 1.5Ma. indicate forward diode approx. value.

Buzzer: Sounds when measure less than 70 ± 20.
7. Battery Test:

RANGE 

CURRENT CONSUNED 

1.5V
9V

50mA
5mA 

±

 0.8% of rdg 

±

3 Digit 

1V

DC Volt

Selection

Area

OHM 

Selection

Area

AC Volt 

Selection

Area

Switch

DC Amp

Selection

Area

Transistor

Selection

Area

10A Jack

Transistor

/hFE Jack

Com Jack

Diode

Selection

Area

“V

Ω

mA”

 Jack