Mode d’emploi 

 Moisture kit 

 "Hygromaster“ 

 Ref. 93214 

PRINCIPLES OF USE 

Using a drill, drill the bracket hole 50 mm deep 
with a 16 mm drill bit (ref. 94194). 

Introduce without delay a special pin (ref. 
93218) on which clipped a cap provided. 
Incubate for 24 closed cap. 

Remove the cap and put the probe in 
HYGOSTICK ankle. 
Wait about 1 hour before connecting the probe 
to the HYGROMASTER to take the 
measurement. 

After an hour turn on. 
Raise the relative humidity value of 
balance (HRE).

 

** Installation of vinyl flooring is possible when the ERH is less than or equal to 85% 
to another coating if the percentage is less than 85% support is considered dry. 
If this measure is not reached, remove the probe, recap the ankle with his hood which will renew the 
operation until the target value. 
After the measure taken, remove the pin and patch using a mortar. 

hygrostick 
probe 

relative 
humidity value 

temperature value 

Summary of Contents for Hygromaster

Page 1: ... Standard functions measurement of humidity and temperature 2 Tables functions off measures 3 setup 3 Functions common to configuration modes 4 Record Setup 4 Device configuration 5 Selecting the surface temperature Port 5 Recording Features PC configuration 6 recording functions manual recording 6 Recording functions reading data 6 ...

Page 2: ...the recorded measurements are displayed in a table and graph to an analysis simple and fast Hygrostick et Humistick The hygromaster is used with a detachable humidity probe for measuring relative humidity and ambient temperature Two types of sensor are available Hygrostick and Humistick The Hygrostick is optimized for measuring the humidity of 30 to 100 RH and can be used with Protimeter ankles to...

Page 3: ...the screen 4 Press repeatedly to display the room temperature RT surface temperature TS the difference in surface temperature over the dew point AT time and date the number series of the probe 5 To turn off press and hold until the display shows OFF Otherwise the unit will automatically turn off after the time set by the user 2 minutes by default after the last button press or RS232 activity Note ...

Page 4: ... probe TA TS ΔT secondary screen scrolling The time is displayed in the upper part of the screen HH MM date in the lower MM DD The serial number of the probe scrolls Storage of measurement in memory Log Press and hold 3 seconds to store measures momentary display of the number recordings and stored data b Configuration Press both buttons simultaneously see details below Button Function Display sym...

Page 5: ...es paramètres se présentent dans l ordre suivant upper part of the screen lower part of the screen Definition of PC configuration meaning Min Max Entry into the mode configuration recording the display is frozen as the buttons are pressed The logging interval is set 15 minutes example 0 No record 24H Delay before the first record 0 No delay 24H If it is not zero count the number remaining and stop...

Page 6: ...um 2 maximum 2 maximum 0 2 The new configuration is saved after pressing With the exception of the function the temperature sensor the settings are saved when the camera is off Probe function temperature of the side port automatically returns to OFF OFF when the camera is off For return to normal operating mode press or any button for 5 seconds at any configuration time f Selection of surface temp...

Page 7: ...mended to check the clock before performing manual recording press as described above to scroll through the time date When replacing batteries the clock is to adjust from a computer as described above 2 The unit OFF press and hold 3 seconds to take a manual check point This works exactly as if the recording was made with the timer as described above There is no requirement to register it is useful...

Page 8: ...g the probe to the HYGROMASTER to take the measurement After an hour turn on Raise the relative humidity value of balance HRE Installation of vinyl flooring is possible when the ERH is less than or equal to 85 to another coating if the percentage is less than 85 support is considered dry If this measure is not reached remove the probe recap the ankle with his hood which will renew the operation un...