Mode d’emploi
Moisture kit
"Hygromaster“
Ref. 93214
PRINCIPLES OF USE
Using a drill, drill the bracket hole 50 mm deep
with a 16 mm drill bit (ref. 94194).
Introduce without delay a special pin (ref.
93218) on which clipped a cap provided.
Incubate for 24 closed cap.
Remove the cap and put the probe in
HYGOSTICK ankle.
Wait about 1 hour before connecting the probe
to the HYGROMASTER to take the
measurement.
After an hour turn on.
Raise the relative humidity value of
balance (HRE).
** Installation of vinyl flooring is possible when the ERH is less than or equal to 85%
to another coating if the percentage is less than 85% support is considered dry.
If this measure is not reached, remove the probe, recap the ankle with his hood which will renew the
operation until the target value.
After the measure taken, remove the pin and patch using a mortar.
hygrostick
probe
relative
humidity value
temperature value