NEXUS CALL SYSTEM
by Rondish
P14
1.3.2 Pre-Install Survey
Rondish recommends using floor plans to propose locations for ZP-01(S) signal repeaters in corridors at
regular intervals, around 40-50m apart. For a multi-story building operating as a single system, you can
offset the positions of repeaters on different floors (
if you don’t care about locating mobile alarms
). The
distances achievable will depend vary according to the structure of the building, with steel and concrete
much lower than wood and drywall.
Once you have proposed installation positions for the ZP-01(S) repeater units, you can visit the site with
your map and test out a few of the locations with the Pegasus range tester.
Place a WCP-11 at the furthest distances from the proposed ZP-01(S) location and test the Pegasus can
receive the signal. If the Pegasus tester will receive alarm and reset signals you can be confident about
the signal reliability into a ZP-01(S) repeater. In particular check the locations in the corners and make
sure the nearest ZP-01(S) is well within range. Pay particular attention when going through multiple
walls.
If TXP-11 are being used on this site, repeat using this device at the furthest distance it will be used, and/or
where there are obstacles blocking the path.
Note: