2
◎
Important safety instructions
……………………………………………………2~3
◎
Technical Data
……………………………………………………………………...3
◎
Warning ……………………………………………………………………………..4~7
◎
Component Identification
…………………………………………………………7
◎
Installation
……………………………………………………………………………7~10
◎
Pressure Relief Procedure………………………………………………………...10~11
◎
Operation instr
uction………………………………………………………………11~13
◎
Airless Sprayer Cleaning Procedure……………………………………………..13
◎
Pressure release procedure………………………………………………………13
◎
Daily Maintain…………………………………………………………………………13
◎
General Repair
Information…………………………………………………………14
◎
Troubleshooting
……………………………………………………………………..15
◎
Parts List
………………………………………………………………………………16-18
◎
Sealing ring replace…………………………………………………………………18
◎
Airless Sprayer Electrical Installation Drawing…………………………………23
※
IMPORTANT SAFETY INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
WARNING
– When using tools, basic precautions should always be followed, including the following:
a) SAVE THESE INSTRUCTIONS-To reduce the risks of fire or explosion, electrical shock and injury to persons, read
and understand all instructions included in this manual. Be familiar with the controls and the proper usage of the
equipment.
b) WARNING-To reduce the risk of fire of explosion:
1) Do not spray flammable or combustible materials near an open flame or sources of ignition such as cigarettes, motors,
and electrical equipment.
2) For units intended for use with only water-based materials-Do not spray or clean with flammable liquids. For use with
water-based liquids only.
3) For units intended for use with only water-based or mineral spirit-type materials with a minimum flash point of
21C°(69.8 F°) Do not spray on clean with liquids having a flash point less than 21C°(69.8 F°)
4) Paint or solvent flowing through the equipment is able to result in static electricity. Static electricity creates a risk of fire
or explosion in the presence of paint or solvent fumes. All parts of the spray system, including the pump, hose
assemble, spray gun, and objects in and around the spray area shall be properly grounded to protect against static
discharge and sparks. Use only conductive or grounded high-pressure airless paint sprayer hoses specified by the
manufacturer.
5) Verify that all containers and collection systems are grounded to prevent static discharge.
6) Connect to a grounded outlet and use grounded extension cords. Do not use a 3 to 2 adapter.
7) Do not use a paint or a solvent containing halogenated hydrocarbons. See operating instructions for examples of these
types of materials.
8) Keep spray area well ventilated. Keep a good supply of fresh air moving through the area. Keep pump assembly in a
well ventilated area. Do not spray pump assembly.
9) Do not smoke in the spray area.
10) Do not operate light switches, engines, or similar spark producing products in the spray area.
11) Keep area clean and free of paint or solvent containers, rags, and other flammable materials.
12) Know the contents of the paints and solvents being sprayed. Read all Material safety Data Sheets (MSDS) and
co
ntainer labels provided with the paints and solvents. Follow the paint and solvent manufacturer’s safety instructions.
13) Fire extinguisher equipment shall be present and working.
c) WARNING-To reduce the risk of skin injection.
1) Do not aim the gun at, or spray any person or animal.