background image

15

RootsScrub B4550C

Ÿ

For  reasons  of  safety  during  cleaning  and/or 

maintenance  work  in  or  on  the  tank,  the  tank  lid  - 
when  lifted  -  must  be  secured  so  as  to  prevent 
accidental closing or tilting down. 

Ÿ

The machine may be taken into operation only if all 

guarding devices are fitted and in protective position. 
As far as possible, cleaning should not be done by 
hand, but using appropriate tools or equipment. 

Ÿ

Maintenance  and  repair  work  may  be  carried  out 

only by means of suitable tools and by the people 
trained  in  the  factory  -  for  reasons  of  safety,  only 
genuine Roots spare parts may be used. 

The electrical equipment of this machine uses a mains 
voltage  of  24  DC.  Easy  access  to  brush  motor  and 
vacuum motor is possible after the upper part of the unit 
has been titled to upside.
The  suction  turbine  has  been  provided  with  a  fuse 
having a rating of 25A. It must be replaced by a fuse of 
same rating. 
The brush motor is protected by a fuse having a rating of 
35A.  When  brush  motor  trips  identify  the  cause  and 
correct it before trying to run the machine. 
The fuses can be changed by removing the rear panel 
assembly.

MAINTENANCE

 - If there should be repeated cases of failure, 

look for the reason. 

 - Any work at the electrical system has to be 

carried out by specialized electricians only.

 

Maintenance Work

Compliance  with  our  recommendations  concerning 
maintenance  work  will  give  you  the  certitude  always 
having  a  machine  at  your  disposal,  which  is  ready  to 
work and in good operating condition.

Please contact your local Roots Multiclean distributor; 
the people there will be glad to perform that work for you. 
There well trained personnel and genuine Roots spare 
parts are at your disposal.

Ÿ

Well  trained  personnel  and  genuine  Roots  spare 

parts are at your disposal. 

Ÿ

In  case  of  any  inquiries  or  orders  for  spare  parts, 

please  always  quote  the  machine's  serial  number 
mentioned on the  nameplate. 

Ÿ

The  name  plate  is  fixed  in  the  rear  side  of  the 

machine.

Ÿ

When cleaning or servicing the machine, and when 

replacing  any  parts,  shut  off  the  machine  and  on 
principle disconnect the power plug from the power 
supply. 

Electrical System

Maintenance Schedule

Daily

Every 

50

Every 

100

Every 

200

Service Hours

Maintenance Schedule

C h e c k   c o n n e c t i o n   -  
extension  cables  and  plugs 
for  good  condition;  discard 
Defective cables immediately 

Empty  and  clean  the  dirty 
water tank 

Check  the  sealing  strips  of 
squeegee for good condition

Check  the  float  for  proper 
operation

Check  the  squeegee  for 
possibly  collected  foreign 
matter and clean it, if required

Check  the  suction  hose 
between squeegee and  Dirty 
water tank

Check the caps of both Fresh 
and  dirty  water  drain  hose; 
c h e c k   t h e m   f o r   s m o o t h 
operation

Remove carbon dust from the 
suction  motor,  check  the 
carbon  brush  for  smooth 
operation and wear; renew as 
required

Check the squeegee sealing 
strips for wear; renew them if 
required
Check  the  brush  for  tight  fit 
and  wear;  renew  them  if 
required
Check the tank lid seal; renew 
if it is required

Check the fresh water infeed 
to the brush

Summary of Contents for RootsScrub B4550C

Page 1: ...ootsScrub B4550C RootsScrub B4550C B4550Cx Walk Behind Floor Scrubber Drier Electric Read this manual completely and understand the instructionsbeforeoperatingthemachine EnglishVersion Owner s Manual...

Page 2: ...2 RootsScrub B4550C...

Page 3: ...is manual Roots Multiclean Ltd RKG Industrial Estate Coimbatore 641 006 India 557350118 00 Rev D 09 17 Prepared by KM NPM TD Dept Description Page No Introduction Know Your Machine Technical Specifica...

Page 4: ...roduct sold within India If the product requires repair or maintenance work to be performed please ensure that you get the machine serviced from an authorised service center or dealer of RMCL to ensur...

Page 5: ...age m2 h 2000 2000 Working Speed up to km h 4 4 Battery Rating V Ah 12 96 Airflow rate L sec 28 28 Vacuum Pressure mm of H2O 1087 1087 Power Supply V 24 24 Total Power W 1000 1000 Brush Motor W 650 65...

Page 6: ...cing operation Adherence to the above general instructions will help avoid the operator from having to read the manual while operating the machine Safety during machine operation The machine is applic...

Page 7: ...tions Damaged parts may only be changed at an authorized service center It is not permitted to use aggressive and corrosive cleaning agents Used batteries with the recycling symbol must not be dispose...

Page 8: ...also substantially reduced If floors are particularly dirty or if wax has to be removed basic cleaning the floor must be treated twice During the first cycle the floor is scrubbed with the cleaning a...

Page 9: ...quipment and cause personal injury LEGEND DESCRIPTION PURPOSE A Main Power Switch Initiates power supply to the system B Brush Motor Switch For On Off C Suction Turbine For On Off Shows information so...

Page 10: ...conds 5 Brush Motor Suction Turbine OFF The brush motor shuts down immediately when switch B 0016 10 BATTERY CHARGING 6 The brush motor suction turbine icons will start flashing just before the batter...

Page 11: ...that the guiding rollers and the brushes catch safely When mounting check the safe catching of rollers and brushes Before cleaning or maintaining the machine as well as before replacing parts of it tu...

Page 12: ...s 2 Mount the new sealing strips by inverse sequence of operation Removal of Squeegee 1 Squeegee 2 Squeegee Knob 3 Squeegee Bracket group Mounting of Squeegee first time Lift squeegee bracket group 3...

Page 13: ...preclude damages at the suction turbine We recommend our agents for cleaning and care which are perfectly adopted to the machine How to operate the machine Refer Controls section of B4550C B4550Cx in...

Page 14: ...er jet or h i g h p r e s s u r e c l e a n i n g e q u i p m e n t as this will endanger its proper working function Remove the Hose from this clamp to drain the water Draining of Dirty water tank Wh...

Page 15: ...ine at your disposal which is ready to work and in good operating condition Please contact your local Roots Multiclean distributor the people there will be glad to perform that work for you There well...

Page 16: ...ry Replace battery Loose battery cable Tighten loose cable Main fuse blown Replace the fuse Main fuse blown Replace the fuse Faulty brush motor or loose cable Contact service Suction turbine does not...

Page 17: ...ated area Make sure to connect the charger to the specified voltage and frequency Ensure that the seat cover is completely open Do not place any objects on the battery Electrolyte is highly corrosive...

Page 18: ...rminals tight and covered with petroleum jelly Keep the machine tank opened while charging to improve ventilation Battery and Charger Batteries connecting diagram The batteries and charger are located...

Page 19: ...harger manufacturer s user manual which is supplied along with the machine Disposal of Batteries Old batteries with this sign are recyclable economic goods and should be brought back into the recyclin...

Page 20: ...20 RootsScrub B4550C NOTES...

Page 21: ...21 RootsScrub B4550C...

Page 22: ...RootsScrub B4550C Roots Multiclean Ltd R K G Industrial Estate Ganapathy Coimbatore 641 006 India Phone 91 422 4330 330 E mail rmclsales rootsemail com Web rootsmulticlean in Toll Free 1800 41 99 77...

Reviews: