6. Care

The  battery  must  be  kept  clean  and  dry  to  prevent 
creeping current. Any liquid in the battery container must 
be extracted and disposed of according to regulations.
Distilled water level shall be maintained at safe level. 
( refer battery manual )

7. Storage

If batteries are out of operation for longer periods, they 
should be stored in fully charged state in a dry, frost free 
room.
In order to ensure that the battery is ready for operation 
at any time, full recharge every three months. When a 
consumer  is  connected  up  (e.g.  measuring  or 
controlling  devices),  it  may  be  necessary  to  recharge 
the battery every two weeks.

8. Faults

The  customer  service  should  be  called  immediately 
when  any  faults  are  discovered  in  battery  or  battery 
charger.

BATTERY INSTRUCTIONS

Ÿ

 

  Kindly  ensure  that  the  Warranty  certificate  of  the 

battery is available at your end.

Ÿ

Kindly  read  the  Do’s  &  Don't’s  of  the  battery, 
understand and follow.

Ÿ

Check the electrolyte level before charging and top it 
up with battery grade distilled water if required.

Ÿ

Match the battery to the correct charger.

Ÿ

Keep the battery well ventilated while charging.

Ÿ

Charge  the  battery  immediately  after  it  is 

discharged.

Ÿ

Keep all inter cell connections and bolted terminals 

tight and covered with petroleum jelly. 

Ÿ

Keep  the  machine  tank  opened  while  charging  to 

improve ventilation.

Battery and Charger

Batteries connecting diagram

Ÿ

The batteries and charger are located in the fresh 

water tank.

Ÿ

The on board charger is located in the fresh water 

tank, mounted on to a special bracket.

Do  not  tamper  with  the  charger 
connections

AGM

LA

Lead Acid (LA) Battery Instructions:

3. Temperature

The battery temperature of 30 °C is rated temperature. 
Higher temperatures shorten the service life and lower 
temperatures  reduce  available  capacity.  45  °C  is  the 
limit  temperature  and  is  not  tolerable  as  operating 
temperature.

4. Electrolyte

The  electrolyte  is  sulphuric  acid  (LA)  stored  in  liquid 
form. The specific gravity of the electrolyte and quantity 
shall be checked weekly.
If  the  quantity  is  low,  refill  with  battery  grade  distilled 
water.

5. Maintenance

Daily maintenance- 

Recharge the battery every time it 

has been discharged.

Weekly maintenance- 

Visual inspection after recharging 

for signs of dirt and mechanical damage.
Maintenance to be carried out every three months

After fully recharging and following a standing period of 
at least 5 hours, the following must be measured and 
Recorded:  – total voltage / – individual voltage

If  noticeable  changes  are  detected  compared  to 
previous  measurements,  or  differences  between  the 
cells or block batteries, the customer service should be 
called for testing or repair.

B1

B2

Summary of Contents for RootsScrub B4550C

Page 1: ...ootsScrub B4550C RootsScrub B4550C B4550Cx Walk Behind Floor Scrubber Drier Electric Read this manual completely and understand the instructionsbeforeoperatingthemachine EnglishVersion Owner s Manual...

Page 2: ...2 RootsScrub B4550C...

Page 3: ...is manual Roots Multiclean Ltd RKG Industrial Estate Coimbatore 641 006 India 557350118 00 Rev D 09 17 Prepared by KM NPM TD Dept Description Page No Introduction Know Your Machine Technical Specifica...

Page 4: ...roduct sold within India If the product requires repair or maintenance work to be performed please ensure that you get the machine serviced from an authorised service center or dealer of RMCL to ensur...

Page 5: ...age m2 h 2000 2000 Working Speed up to km h 4 4 Battery Rating V Ah 12 96 Airflow rate L sec 28 28 Vacuum Pressure mm of H2O 1087 1087 Power Supply V 24 24 Total Power W 1000 1000 Brush Motor W 650 65...

Page 6: ...cing operation Adherence to the above general instructions will help avoid the operator from having to read the manual while operating the machine Safety during machine operation The machine is applic...

Page 7: ...tions Damaged parts may only be changed at an authorized service center It is not permitted to use aggressive and corrosive cleaning agents Used batteries with the recycling symbol must not be dispose...

Page 8: ...also substantially reduced If floors are particularly dirty or if wax has to be removed basic cleaning the floor must be treated twice During the first cycle the floor is scrubbed with the cleaning a...

Page 9: ...quipment and cause personal injury LEGEND DESCRIPTION PURPOSE A Main Power Switch Initiates power supply to the system B Brush Motor Switch For On Off C Suction Turbine For On Off Shows information so...

Page 10: ...conds 5 Brush Motor Suction Turbine OFF The brush motor shuts down immediately when switch B 0016 10 BATTERY CHARGING 6 The brush motor suction turbine icons will start flashing just before the batter...

Page 11: ...that the guiding rollers and the brushes catch safely When mounting check the safe catching of rollers and brushes Before cleaning or maintaining the machine as well as before replacing parts of it tu...

Page 12: ...s 2 Mount the new sealing strips by inverse sequence of operation Removal of Squeegee 1 Squeegee 2 Squeegee Knob 3 Squeegee Bracket group Mounting of Squeegee first time Lift squeegee bracket group 3...

Page 13: ...preclude damages at the suction turbine We recommend our agents for cleaning and care which are perfectly adopted to the machine How to operate the machine Refer Controls section of B4550C B4550Cx in...

Page 14: ...er jet or h i g h p r e s s u r e c l e a n i n g e q u i p m e n t as this will endanger its proper working function Remove the Hose from this clamp to drain the water Draining of Dirty water tank Wh...

Page 15: ...ine at your disposal which is ready to work and in good operating condition Please contact your local Roots Multiclean distributor the people there will be glad to perform that work for you There well...

Page 16: ...ry Replace battery Loose battery cable Tighten loose cable Main fuse blown Replace the fuse Main fuse blown Replace the fuse Faulty brush motor or loose cable Contact service Suction turbine does not...

Page 17: ...ated area Make sure to connect the charger to the specified voltage and frequency Ensure that the seat cover is completely open Do not place any objects on the battery Electrolyte is highly corrosive...

Page 18: ...rminals tight and covered with petroleum jelly Keep the machine tank opened while charging to improve ventilation Battery and Charger Batteries connecting diagram The batteries and charger are located...

Page 19: ...harger manufacturer s user manual which is supplied along with the machine Disposal of Batteries Old batteries with this sign are recyclable economic goods and should be brought back into the recyclin...

Page 20: ...20 RootsScrub B4550C NOTES...

Page 21: ...21 RootsScrub B4550C...

Page 22: ...RootsScrub B4550C Roots Multiclean Ltd R K G Industrial Estate Ganapathy Coimbatore 641 006 India Phone 91 422 4330 330 E mail rmclsales rootsemail com Web rootsmulticlean in Toll Free 1800 41 99 77...

Reviews: