Page 10
Installation and commissioning
© 2017 Ropam Elektronik
3. Installation and commissioning
Basic requirements.
The system is based on BasicGSM 2 and the other required components are for installation by a
qualified installer with appropriate (required and required by country) permits and permissions to
connect (interference) to 230V / AC systems and low voltage installations. The units should be
installed indoors, with normal humidity (RH = 20% - 90% max non-condensing) and temperatures in
the range -
10 ° C ... + 55 ° C. Before installing, make a load balancing of the power supply. Because
the system power supply is designed for continuous operation and does not have a power switch,
proper overload protection in the power supply circuit must be provided. Also tell the user how to
disconnect the power supply from the power supply (usually by splitting and marking the appropriate
fuse in the fuse box). Electrical installation should be carried out in accordance with applicable
standards and regulations.
When selecting the module mounting location, the communication module should be guided by the
following criteria:
- GSM network coverage (SIM card operator used for the module)
- the GSM antenna and other system components (eg power supply) must be in the protected area,
- availability and distance from alarm / triggering sources (eg control panel);
- availability or possibility of installation in the immediate vicinity of the power source:
- availability of facilities for third parties and sabotage tests,
- keep a safe distance from sources of possible interference (eg 230Vac power lines - buildings, radio
transmitters, etc.).
Power requirements in accordance with PN-EN 50131-6.
The PS * type A ** power supply should supply electrical power to I & HAS *** components without
interruption. To meet the appropriate degree 1,2 or 3 acc. EN 50131-6, the emergency power supply
must run at a minimum of Td (implemented by limiting the power consumption from the power supply:
Id + Iz) and the battery charging time to 80% of the rated capacity can not exceed the time: TQ0,8C.