Page 31
System configuration
© 2017 Ropam Elektronik
MOBILE APPLICATION:
control of output from RopamBasic mobile application and RopamDroid.
ALARM:
output active when an alarm occurs. (def. normal input).
INDICATOR:
active output (indicator) when the module goes into standby mode, if this option is
enabled, the time settings in the "TIME [s]" field are ignored.
ARM CA Pulse:
turn on the output to a short pulse (0,7s), eg. The purpose of arming external alarm
central.
DISARM CA Pulse:
turn on the output to a short pulse (0,7s), for example to disarmam external alarm
central.
ARM/DISARM CA IMPULS:
switch on / off output fot short pulse (0.7s), eg to arming / disarming the
external alarm panel.
LOGIC PROCESSOR -
the output activated by LogicProcessor, the process of overrid actions for
module outputs. If the LP control option is selected, then other triggering changes functions of output
state are overwritten by the LogicProcessor loop! The output operation based on the LP allows to
achieve a result based on many of system resources which greatly facilitates advanced use of module
and reduces the quantity of external peripherals needed to carry out more complex operations using
the module BasicGSM 2.
FAILURE SUMMARY
output is active when a failure occurs.
AC NO
- active when AC power failure occurs, AC failure delay time (0s-165mins configured in
COMMUNICATIONS, TESTS, COUNTERS)
TIMER 1, TIMER 2, TIMER 3, TIMER 4:
output on / off by timers available in the system.
NUMBERS AUTHORIZED TO CLIP CONTROL OUTPUT
The option, after selecting, entitles phone numbers entered in the NUMERS tab to control the output
with the option CLICK ON: CLIP Bell.
COMMENTS:
- Please note that the phone number from which you want to control the output can not be
"reserved".
- responses to incoming calls are configured in the SYSTEM OPTIONS tab.