background image

5

Gas Supply Requirements

Observe all governing codes and ordinances. 

IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest 
edition. 

Type of Gas 

Natural Gas:

This range is design-certified by CSA International for use with 
Natural gas or, after proper conversion, for use with LP gas. 

This range is factory set for use with Natural gas. See “Gas 
Conversions” section. The model/serial rating plate located 
on the frame behind the storage drawer has information on 
the types of gas that can be used. If the types of gas listed do 
not include the type of gas available, check with the local gas 
supplier.

LP Gas conversion:

Conversion must be done by a qualified service technician.

No attempt shall be made to convert the appliance from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting the serving gas supplier. See “Gas 
Conversions” section.

Gas Supply Line 

Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the 
range location. A smaller size pipe on longer runs may result 
in insufficient gas supply. Pipe-joint compounds that resist 
the action of LP gas must be used. Do not use TEFLON

®†

 

tape. With LP gas, piping or tubing size can be ½" (1.3 cm) 
minimum. Usually, LP gas suppliers determine the size and 
materials used in the system.

Flexible metal appliance connector:

If local codes permit, a new C.S.A. design-certified, 
4 - 5 ft (122 - 152.4 cm) long, ½" (1.3 cm) or 
¾" (1.9 cm) I.D., flexible metal appliance connector may 
be used for connecting range to the gas supply line. 

A ½" (1.3 cm) male pipe thread is needed for connection 
to the female pipe threads of the inlet to the appliance 
pressure regulator. 

Do not kink or damage the flexible metal tubing when 
moving the range.

Rigid pipe connection: 

The rigid pipe connection requires a combination of pipe 
fittings to obtain an in-line connection to the range. The rigid 
pipe must be level with the range connection. All strains must 
be removed from the supply and fuel lines so range will be 
level and in line.

Must include a shutoff valve: 
The supply line must be equipped with a manual shutoff 
valve. This valve should be located in the same room but 
external to the range. It should be in a location that allows 
ease of opening and closing. Do not block access to shutoff 
valve. The valve is for turning on or shutting off gas to the 
range.

Gas Pressure Regulator

The gas pressure regulator supplied with this range must be 
used. The inlet pressure to the regulator should be as follows for 
proper operation:

Natural Gas:

Minimum pressure: 6" WCP

Maximum pressure: 14" WCP

LP Gas:

Minimum pressure: 11" WCP

Maximum pressure: 14" WCP

Contact local gas supplier if you are not sure about the inlet 
pressure.

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 

Examples of a qualified person include: 

licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.

A. Gas supply line
B. Shutoff valve “open” position

C. To range

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

A

B

C

Summary of Contents for FGS326RD

Page 1: ...what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards tha...

Page 2: ...uilding Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Clear the room building or area of all occupants In the State of Massachusetts the following installation instructions apply Ins...

Page 3: ...trical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section Contact a qualified floor covering installer to check that the floor covering can withstand at least 200 F 93 C Use an insulated pad or 0 64 cm plywood under range if installing range over carpeting IMPORTANT Some cabinet and building materials are not de...

Page 4: ...MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a separate circuit serving only this range be provided Electronic ignition systems operate within wide voltage limits but proper grounding and polarity are necessary Che...

Page 5: ...e connector may be used for connecting range to the gas supply line A 1 3 cm male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator Do not kink or damage the flexible metal tubing when moving the range Rigid pipe connection The rigid pipe connection requires a combination of pipe fittings to obtain an in line connection to the range Th...

Page 6: ...d or hardboard in front of range Using 2 or more people stand range back up onto cardboard or hardboard InstallAnti TipBracket Contact a qualified floor covering installer for the best procedure for drilling mounting holes through your type of floor covering Before moving range slide range onto shipping base cardboard or hardboard 1 Remove template from the anti tip bracket kit found inside the ov...

Page 7: ... bracket 5 If installing the range in a mobile home you must secure the range to the floor Any method of securing the range is adequate as long as it conforms to the standards in the Location Requirements section LevelRange Place rack in oven Place level on rack first side to side then front to back If range is not level pull range forward until rear leveling leg is removed from the anti tip brack...

Page 8: ...osition the system creates a spark to light the burner This sparking continues as long as the control knob is turned to LITE When the oven control is turned to the desired setting sparking occurs and ignites the gas Check Operation of Cooktop Burners Standard Surface Burners Push in and turn each control knob to the LITE position The flame should light within 4 seconds The first time a burner is l...

Page 9: ... flame spreader and pull forward to remove tabs from rear of oven Using a mirror Insert a mirror to one side of the burner Look into the mirror to check flame 4 Push the BAKE pad 5 Press the START pad The oven bake burner should light within 8 seconds under certain conditions it may take the burner up to 50 to 60 seconds to light Electronic igniters are used to light the bake and broil burners Ref...

Page 10: ...nstalled If there is an extra part go back through the steps to see which step was skipped 2 Check to be sure you have all of your tools 3 Dispose of recycle all packaging materials 4 Check to be sure the range is level See Level Range 5 Use a mild solution of liquid household cleaner and warm water to remove waxy residue caused by protective shipping material Dry thoroughly with a soft cloth For ...

Page 11: ...emove the burner base NOTE Reinstall one of the screws through the range cooktop to hold the orifice spud holder in place while removing and replacing the orifice spuds A To range B Manual shutoff valve closed position C Gas supply line WARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have...

Page 12: ...he burner base using both screw 7 Replace burner cap 8 Repeat steps 1 7 for the remaining burners To Convert Oven Bake Burner 1 Remove oven racks 2 Use a combination wrench to turn the orifice hood down snug onto pin about 2 to 2 turns IMPORTANT Do not overtighten The oven bake burner flame cannot be properly adjusted if this conversion is not made See Adjust Oven Bake Burner Flame section To Conv...

Page 13: ... an access cover must be removed from the gas pressure regulator IMPORTANT Do not remove the gas pressure regulator Gas pressure regulator 3 Remove plastic cover from gas pressure regulator cap 4 Turn gas pressure regulator cap counterclockwise with a combination wrench to remove NOTE Do not remove the spring beneath the cap 5 Turn over the gas pressure regulator cap and reinstall on regulator so ...

Page 14: ... loosen the orifice hood away from the pin about 2 to 2 turns The oven broil burner flame cannot be properly adjusted if this conversion is not made See Adjust Oven Broil Burner Flame section ReplaceOvenRacks Storageor WarmingDrawer Replace oven racks in oven cavity Insert storage drawer or warming drawer into slide rails on sides of drawer opening Lift front of drawer slightly and push firmly to ...

Page 15: ...15 Notes ...

Page 16: ...TIP BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall Left edge Top edge 9758657 2005 All rights reserved 3 05 Printed in U S A ...

Reviews: