Device functions
Version 2
UPT-6012
Seite 19
fluctuate, or temporarily deviate in the wrong direction. This kind of behaviour would indicate that the U
R
meas-
urement cable was laid incorrectly.
If an error code is displayed, proceed as described in section 8.19 "Error messages" on page 47.
10.Optimize the heating and control process either by adjusting the correction factor Co in the parameter data (
file) or using (
section 8.7.8 "Correction factor Co" on page 35). Any production-related resistance tolerances
of the heating element are compensated in this way.
8
Device functions
See also section 6.6 "Wiring diagram (standard)" on page 13.
8.1
LEDs and controls
UPT-6012
ECAT ERROR
(red LED)
ECAT RUN
BUS POWER
24V POWER
(green LED)
(green LED)
(green LED)
Lit or blinking to indicate
EtherCAT network errors.
Lit as long as there are no
communication errors.
Lit if external 24VDC power
supply is present.
Lit if internal power supply for
EtherCAT interface is OK.
12 13 14 15 16 17 18
9
8
6
5
10
11
7
4
3
2
1
OUT
IN
L/
A
L/
A
Vis ua l
OUTPUT
HEAT
ALARM
ECAT ERROR
ECAT RUN
BUS POWER
24V POWER
AC
!
P ROCE S S CONTROL
E QUI P M E NT
E 464680
www.
.de
ROPEX
Made in Germany
L/A
(green LED)
Lit if connection exists to
EtherCAT.
Blinking if EtherCAT frames are
transmitted.
(red LED)
(yellow LED)
ALARM
(yellow LED)
OUTPUT
HEAT
AUTOCAL
(green LED)
Lit while AUTOCAL process is
executing.
Indicates pulses in
measurement mode. In control
mode, luminous intensity is
proportional to heating current.
Lit during heating phase.
Lit or blinking to indicate fault.
CIRUS