Device functions
Seite 32
UPT-6012
Version 2
4011
Temperature-OK-bit (output 1)
RW
active, if
ACT=SET
off (0),
active, if ACT=SET
(1)
active, if ACT=SET
with latch (2)
UINT8
4012
Hold mode
RW
off
off (0), on (1),
2 seconds (2)
UINT8
4300
System date
RW
UINT32
4301
System time
RW
UINT32
4302
Operating hours
RO
0
0…999999999
(0…99999999.9h)
UINT32
4303
Total cycle counter
RO
0
0…999999999
UINT32
4304
Total cycle counter, clearable
RW
0
0…999999999
UINT32
4305:00
Cycle counter per channel, clearable
RO
8
UINT8
4305:01
SubIndex 001
RW
0
0…999999999
UINT32
4305:02
SubIndex 002
RW
0
0…999999999
UINT32
4305:03
SubIndex 003
RW
0
0…999999999
UINT32
4305:04
SubIndex 004
RW
0
0…999999999
UINT32
4305:05
SubIndex 005
RW
0
0…999999999
UINT32
4305:06
SubIndex 006
RW
0
0…999999999
UINT32
4305:07
SubIndex 007
RW
0
0…999999999
UINT32
4305:08
SubIndex 008
RW
0
0…999999999
UINT32
4306:00
Calibration deviation
RO
UINT8
4306:01
SubIndex 001
RW
0
-10000…10000
(-100.00…100.00%)
INT16
4306:02
SubIndex 002
RW
0
-10000…10000
(-100.00…100.00%)
INT16
4306:03
SubIndex 003
RW
0
-10000…10000
(-100.00…100.00%)
INT16
4306:04
SubIndex 004
RW
0
-10000…10000
(-100.00…100.00%)
INT16
4306:05
SubIndex 005
RW
0
-10000…10000
(-100.00…100.00%)
INT16
4306:06
SubIndex 006
RW
0
-10000…10000
(-100.00…100.00%)
INT16
4306:07
SubIndex 007
RW
0
-10000…10000
(-100.00…100.00%)
INT16
Index:
Sub
index
Name
Acces
s
Default value
1
Range
Data
type