Device functions
Seite 38
UPT-6012
Version 2
The various hold modes are shown below:
The "Hold mode" function must be activated in the parameter data (
section 8.7 "Object dictionary" on page 28)
(default setting: hold mode off).
8.8
Integrated web server
The integrated web server enables quick and easy access to status information and parameter values of the tem-
perature controller via the existing Ethernet connection. The device protocol can additionally be read out and dis-
played. A graph showing the last 5 seconds of a heating impulse allows a rapid qualitative evaluation of the con-
trolled system.
The latest version of the operating instructions can be downloaded from the ROPEX website by clicking on the
picture of the device on any page. To make sure this latest version is always available in any selectable language,
the instructions are not stored in the device; you must therefore have an Internet connection in order to access the
operating instructions.
You can go direct to the official ROPEX website by clicking on the ROPEX logo in the top right-hand corner.
The web server uses JavaScript and has been successfully tested with Internet Explorer 9, 10, and 11 as well as
with Microsoft Edge. It also works with the latest version of the Safari and Firefox browsers.
ACTUAL
temperature
ST bit
1
T
t
t
0
0
Hold off
T
t
0
ACTUAL indication
Hold on
T
t
0
Hold 2 s
T
t
0
Hold
Hold
Hold
Hold
End of
heatsealing phase
2 s
2 s