Device functions
Page 28
RES-5008
Version 2
9.2.3
Settings menu
The required parameters are set in the Settings menu (
section 9.4 "Menu structure" on page 29)
9.2.4
Error message
The fault diagnosis function of the controller is always active. A detected error is always reported in the form of an
error message on the display (
section 9.24 "System monitoring/alarm output" on page 46).
9.3
Menu navigation
9.3.1
Menu navigation without alarm
You can navigate through the various menu items using the “MENU” button.
• Briefly press (< 2 s) the “MENU” button to switch to the next menu item.
• Pressing the “MENU” button longer (> 2 s) always switches back to the home position.
Exception:
Controller
is in alarm state. Then there is a return to the alarm menu.
• If no key is pressed for 30 s, there is a return to the home position
Exception:
There is no automatic return
from the positions “AC” [
A
uto
C
al] and “AL” [
AL
arm] after waiting for 30 s.
9.3.2
Menu navigation in the event of an alarm
In the event of an alarm, the display on the terminal returns to the Alarm menu.
• Errors can be acknowledged by pressing the “RESET” button (
section 9.24 "System monitoring/alarm
output" on page 46). The display then changes to the home position.
• Errors can be eliminated with the AUTOCAL function. By pressing the “MENU” key briefly (< 2 s) it is changed
to the menu position “AC” [
A
uto
C
al] and the function AUTOCAL is started by pressing the “ENTER” key
(
section 9.8 "Automatic zero calibration (AUTOCAL)" on page 33).