Hold mode
If the display of the terminal T-408-1 is in the basic position “°C”, the ACTUAL temperature is indicated.
The properties of the display for the ACTUAL temperature can be changed in the menu item “HO” [
HO
ld].
The following settings are possible:
1.
“OFF”
(factory setting)
When the home position is shown in the display, the real ACTUAL temperature is always shown.
2.
“On”
When the home position is shown in the display, the current ACTUAL temperature at the end of the last sealing
phase is always shown. After the regulator is switched on, the real ACTUAL temperature is displayed until
the end of the first heating phase.
3.
“On2”
At the end of a sealing phase, the current ACTUAL temperature is displayed as a display value for another
2 seconds. Subsequently, the ACTUAL temperature is displayed in real time again up to the end of the next
sealing phase.
CAUTION
The Hold Mode only affects the value shown on the display. The actual value output always shows
the actual temperature in real time for all settings.