Device functions
Version 2
RES-5008
Page 37
The different Hold modes are depicted in the following image:
While the temperature value is displayed in Hold mode, the green “HOLD” LED at the terminal lights up.
9.12
Temperature unit Celsius/Fahrenheit
The unit for the temperature display and temperature input can be switched between Celsius (°C) and
Fahrenheit (°F). The display of the T-408-1 terminal must be in the home position.
NOTE
The temperature unit can be changed while the RESISTRON
®
Temperature Controller
RES-5008 is in operation.
ACTUAL-
temperature
START-
Signal
24 VDC
T
t
t
0
0
Hold OFF
T
t
0
ACTUAL display
Hold On
T
t
0
Hold On2
T
t
0
Hold
Hold
Hold
Hold
End
Sealing phase
2 s
2 s