Device functions
Page 46
RES-5008
Version 2
With the ROPEX visualisation software ROPEXvisual
®
the following may happen
• Error messages may be read out
• Temperature curves may be recorded
• Status bits may be displayed
• Parameters may be set
• Manual triggering of sealing pulses can be generated during startup
The ROPEX-Visualisation software ROPEXvisual
®
is intended for startup and the error diagnosis. Permanent
records of the sealing parameters cannot be created with this. The recording of the sealing parameters or status
bits must be done within the machine control. A separate document is available for the ROPEX-visualisation soft-
ware ROPEXvisual
®
. The software and the documentation are available in the
“Visual”).
9.23
AUX interface
Internal interface for diagnosis and maintenance. The interface is currently not available.
9.24
System monitoring/alarm output
To increase the operational safety and to avoid incorrect seals, the RESISTRON
®
Temperature Controller
RES-5008 has a differentiated error message and diagnosis. Both the outer wiring and the internal system are
monitored by hardware and software measures. The system monitoring supports the operator in localising a
defective operating status.
A system malfunction is reported or differentiated through the following elements.
A.)
Terminal T-408-1: Display of an error message in the display of the terminal:
The cause of the fault can be localised quickly and easily through the displayed error number. A list of the possible
error numbers is included in section 9.25 "Error messages" on page 48.
B.)
RESISTRON
®
Temperature Controller RES-5008: Red LED “ALARM” on the controller (
"Display elements and operating elements" on page 26) with three states:
0
5
1 2
34
6
7
8 9
AUX
CONF
IG
URAT
IO
N
ALA
RM
OUT
PU
T
ENER
GIZ
ED
(
)
A T
ALARM
-
DEE
NE
RG
IZ
ED
HOLD
PREHEAT
SEALHEAT
ENTER
HAND
RESET
ROPEX
T-408