4. Instructions for use
4.1 Installation Interfaces
4.1.1 Construction
The wall must be of a suitable material for screws and approved
for wet rooms.
Note the maximum tensile load of the top
screws and ensure that both the structure of the wall and
choice of rawl plugs can withstand the force.
The grey-shaded area states the minimum area for
reinforcement of the wall.
Load tested in accordance with DS/ISO 17966:2016
max. user weight:
150kg
Max. tensile load of top screws:
76 kg (745N)
4.1.2 Plumbing
The drain is Ø32 (1 ¼”).
The water supply ends with 2 (two) 90° stop valves with
½” outside thread pointing upward.
All hoses for water and drain installations must be flexible
to ensure free and unhindered adjustments within the
height adjustment range of cm (the upper side of the
washbasin).
NOTE:
All dimensions are based on a washbasin height
referenced off the individual user’s measurements. Those
measurements are based on the height from the floor to
the top of the user’s legs, when seated in their
wheelchair. If a drastic change of this height is required,
the recommended dimensions must be changed
accordingly.