Strawberry Server
User and Hardware Manual
38
Changing the Hot Swappable Fan
If a fan has failed, the system alarm will beep and the Fan Fault LED will light up. In addition, the
fan board will display a fault LED for the defective fan. Follow these procedures to replace the
failed fan.
CAUTION Be sure the power is not applied and the fans are stopped completely
before removal.
ATTENTION Assurez-vous que le pouvoir n'est pas appliqué et les ventilateurs sont
arrêtés avant de les enlever complètement.
1. After determining which fan has failed, turn off the power to the system.
2. Unplug the fan wiring from the serverboard and remove the failed fan.
3. Place the new fan into the vacant space in the housing while making sure the
arrows on the top of the fan (indicating air direction) point in the same direction
as the arrows on the other fans.
4. Reconnect the fan wiring to the exact same chassis fan header as the previous
fan used.
5. Power up the system and check that the fan is working properly before replacing
the chassis cover.
Replacing a defective RAID Hard Disk Drive
Follow the instructions below to remove the Hard Disk Drive Tray from the chassis:
Removing the Hard Drive from the chassis
1. Press the release button on the drive tray. This extends the drive bay handle.
2. Use the handle to pull the drive out of the chassis.
De-installing the Hard Drive from drive tray
CAUTION Always maintain an ESD environment when handling the hard drive
components.
ATTENTION Toujours maintenir un environnement EDD lors de la manipulation des
composants du disque dur.