53-04127A 05FEB08
20
circuits on the board. TP6 (Black near J6) is the common for all measurements. Readings
should be as follows:
Test Point
Function
Voltage
TP1 (Red)
Regulated Power
9.8 -10.2 VDC (10 VDC nominal.)
TP2 (Red)
Regulated Power
4.7 - 5.3 VDC (5 VDC nominal)
TP3 (Yel)
Regulated Power
-5.7
– 6.3 VDC (-6 VDC nominal)
TP5 (Red)
Regulated Power
5.7
– 6.3 VDC (+6 VDC nominal)
J5:3
Unregulated Power
11 VDC < Input Voltage < 30 VDC
Variations in voltage from those tabulated above may be helpful in analyzing a fault. If
camera operation is less than satisfactory at this point, ROS's Technical Services
Department should be contacted for assistance.